Zeroing the BXG-1000 Gage Using the MIC TRAC (continued)
17. Turn the indicator dial on the BXG-1000 gage
to align the needle with zero.
18. Tighten the indicator clamp.
Note:
Note the position of the small revolution
counter on the indicator before removing
the gage. Place a piece of masking tape on
the side of the gage and record the dial
setting of the small revolution counter to
eliminate incorrect indicator readings.
19. Set a frequency for verifying the zero setting of
all gages. As a minimum, the BXG-1000 gage
should be zeroed on the MIC TRAC once
during each shift to ensure accurate readings.