FIRST AID MEASURES

 

 

Eye: 

No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.

 

Skin: 

No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material 

from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

 

Ingestion: 

No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical advice.

 

Inhalation: 

No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to 

fresh air. Get medical attention if coughing or respiratory discomfort occurs.

 

Note to Physicians: 

In an accident involving high

-

pressure equipment, this product may be injected under the skin. Such an accident 

may result in a small, sometimes bloodless, puncture wound. However, because of its driving force, material injected into a fingertip can 

be deposited into the palm of the hand. Within 24 hours, there is usually a great deal of swelling, discoloration, and intense throbbing 

pain. Immediate treatment at a surgical emergency center is recommended.

 

 

FIRE

 

 

Leaks/ruptures in high pressure system using materials of this type can create a fire hazard when in the vicinity of ignition sources (e.g. 

open flame, pilot lights, sparks, or electric arcs).

 

 

FLAMMABLE PROPERTIES:

 

Flashpoint: 

(Cleveland Open Cup) 178 °C (352 °F) Minimum

 

 

EXTINGUISHING MEDIA: 

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

 

 

PROTECTION OF FIRE FIGHTERS:

 

Fire Fighting Instructions: 

This material will burn although it is not easily ignited. See Section 7 for proper handling and storage. For fires 

involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self

-

contained breathing 

apparatus.

 

Combustion Products: 

Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and gases including 

carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.

 

 

ACCIDENTAL RELEASE MEASURES

 

 

Protective Measures: 

Eliminate all sources of ignition in vicinity of spilled material. 

 

Spill Management: 

Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, 

surface water or groundwater. Clean up spill as soon as possible. Use appropriate techniques such as applying non

-

combustible 

absorbent materials or pumping. Where feasible and appropriate, remove contaminated soil. Place contaminated materials in disposable 

containers and dispose of in a manner consistent with applicable regulations.

 

 

ECOLOGICAL INFORMATION

 

 

Waste disposal: 

In accordance with all environmental regulations applicable to your area.

 

 

Spillage: 

Prevent entry into drains, sewers and water course. Soak up with diatomaceous earth or other inert material. Store in 

appropriate container for disposal.

 

 

Ecotoxicity: 

This material is expected to be harmful to aquatic organisms and may cause long

-

term adverse effects in

 

the aquatic environment. The ecotoxicity hazard is based on an evaluation of data for the components or a similar material.

 

 

HANDLING

 

 

Precautionary Measures: 

DO NOT USE IN HIGH PRESSURE SYSTEMS in the vicinity of flames, sparks and hot surfaces. Use only in 

well ventilated areas. Keep container closed. Keep out of the reach of children.

 

General Handling Information: 

Avoid contaminating soil or releasing this material into sewage and drainage systems and bodies of 

water.

 

Static Hazard: 

Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this 

hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the 

potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash 

filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate 

mitigating procedures.

 

 

 

DISPOSAL CONSIDERATIONS

 

 

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal. Place 

contaminated materials in containers and dispose of in a manner consistent with applicable regulations.

 

DEXRON® III OIL SAFETY DATA

 

Summary of Contents for GB743V

Page 1: ...AR YOU GB743V ORIGINAL INSTRUCTIONS INSTALLATION TOOL GAGE BILT MADE in USA 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions1 gagebilt com www gagebilt com S...

Page 2: ...Technical Specifications 4 Description of Functions 5 Warnings 6 Principle of Operation 7 How to set up the GB743V 8 How to use the GB743V 9 Maintenance 10 Filling and Bleeding 11 Troubleshooting How...

Page 3: ...subsequent user in repair ing or replacing defective goods or if the goods covered by this warranty are reworked or subjected to any type of additional processing This warranty is void if Seller is no...

Page 4: ...d rivets It weighs 6 25 lbs 2 83 kg and can be operated in any position It has a 900 22 86 mm fastener setting stroke and a rated pull load of 4 000 lbs 17 8 kN with 90 psi 6 2 bar of air pressure at...

Page 5: ...ASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS DESCRIPTION OF FUNCTIONS Actuator Handle Assembly Head Cylinder Assembly Air Inlet Vacuum Assembly Bottle Bushing and Cap assembly Nose Assembly Hang...

Page 6: ...maintain and replace the consumable inserted tool as recommended in the instruction handbook to prevent an unnecessary increase in noise 6 If the power tool has a silencer always ensure that it is in...

Page 7: ...the head cylinder assembly The internal components of the attached nose assembly are also moving with the piston to start the fastener installation When the fastener installation is completed the air...

Page 8: ...e the assembly power tool for non threaded mechanical fasteners WARNING Operator MUST read and understand all warnings and cautions WARNING It is required that eye protection hearing protection and sa...

Page 9: ...their application Ensure there is adequate clearance for tool and operator s hands before proceeding Keep fingers clear of any moving parts Keep fingers clear from fasteners and installed materials Se...

Page 10: ...operators is necessary in maintaining full productivity and reducing downtime Keep nose assemblies especially jaws clean and free of chips and debris Lube jaws and collet surfaces that jaws ride on wi...

Page 11: ...4136 and air piston assembly 744121 completely down 2 Fill handle assembly 744129 power cylinder 743131 and the oil passage on top of handle assembly 744129 with automatic transmission oil Dexron III...

Page 12: ...ings on valve sleeve 743144 valve spool assembly 743142 and valve plug 744142 If worn or damaged replace Valve sleeve removal tool 744152 is recommended 6 FASTENER STEM JAMMED IN NOSE ASSEMBLY a Nose...

Page 13: ...r all applicable materials WARNING When operating repairing or overhauling tool wear approved eye protection Do not look in front of tool or rear of tool when installing fastener WARNING Ensure air ho...

Page 14: ...including pin slotted 400608 from the handle assembly 744129 2 Insert a 5 8 open end box wrench adjustable wrench around actuator assembly air 704130 3 Loosen the actuator assembly air 704130 4 Remove...

Page 15: ...m bottom of handle assembly 744129 6 After removal of air piston assembly 744121 slide piston rod assembly 744136 back up to the end of its travel Using packing plug wrench assembly 704150 remove pack...

Page 16: ...16 REV 4 23 GB743V SN 2259 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS PARTS LIST...

Page 17: ...17 REV 4 23 GB743V SN 2259 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS PARTS LIST...

Page 18: ...ds will be evolved when this material undergoes combustion ACCIDENTAL RELEASE MEASURES Protective Measures Eliminate all sources of ignition in vicinity of spilled material Spill Management Stop the s...

Page 19: ...0286 30824 703401 8T TLR RIVET 1 4 8TLR 743 24V 1 10246 30824 703401 8TLR 3 16 C6 734A 20V 2 C6 1 4 C8 734A 20V 2 4 C8 3 16 PH6 734A 20V 2 4 PH6 1 4 PH8 734A 20V 2 4 PH8 1 YOU CAN CHANGE THE 743 24V N...

Page 20: ...lbs 3 29 kg Pull load 4 000 lbs 17 79 kN 5ftHyd HosesarerecommendedwithuseofBackpack Additional custom lengths are available GB743SR Stroke 900 22 86 mm Hand held weight 1 75 lbs 79 kg Entire tool we...

Page 21: ...series installation tools fastener specific by adding the appropriate suffix see selection chart Alternative Styles Sold Separately V DESIGNATION PINTAIL COLLECTION BOTTLE VT DESIGNATION PINTAIL EVAC...

Page 22: ...hey fit directly on the GB743 Installation Tool L Part Number Equivalent to 2 703002 743A50 4 703004 6 703006 Extensions Sold Separately Tool Stroke Depth Gage A 1935 Sold Separately GB743V ACCESSORIE...

Page 23: ...23 REV 4 23 GB743V SN 2259 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS This page intentionally left blank...

Page 24: ...d custom kits tailored to your needs Contact us for more information CE Approved TEFLON IS REGISTERED TRADEMARK OF E I DUPONT DE NEMOURS CO LUBRIPLATE IS A REGISTERED TRADEMARK OF FISKE BROTHERS REFIN...

Reviews: