background image

7/11 REV 3/14 

WARNING

 

Do not pull fastener unless it is placed

 

in an 

assembly, pin will eject forcibly

 

when pintail breaks 

off. Severe

 

personal injury may result. 

WARNING

 

Do not operate without Stat-O-Seal

 

(S572) and cap 

screws (402482). Pressurized

 

hydraulic fluid may 

cause severe

 

personal injury.

 

WARNING

 

When operating, repairing or overhauling tool, wear 

approved eye protection. Do not look in front of 

nose assembly or rear of tool when installing 

fastener.

 

WARNING

 

Always disconnect tool from power

 

before 

performing any maintenance

 

to any tool or nose 

assembly.

 

Ensure

 

that all connections are proper 

and

 

there are no visible leaks from tool

 

or hoses 

before connecting to power. 

WARNING

 

Do not operate if deflector, bottle,

 

catcher  bag or 

vacuum tube is

 

removed or damaged, broken

 

pintails may eject forcibly from rear of tool. Severe 

personal injury

 

may result. 

CAUTION

 

Ensure that nose assembly and tip

 

are properly 

matched for the

 

fastener being installed. 

CAUTION

 

Keep Nose Assemblies clean and free

 

of chips and 

debris. 

WARNING

 

Be sure there is adequate clearance for

 

tool and 

operator's hands before

 

proceeding. Keep fingers 

clear of any moving parts. Keep fingers clear from

 

fasteners and installed materials.

 

Severe personal 

injury may result.

 

CAUTION

 

Do not use beyond the design intent. 

WARNING

 

Tool must be maintained in a safe working 

condition at all times and examined on a regular 

daily basis for damage or wear.  Any repair should 

be done by qualified personnel trained on Gage Bilt 

procedures. 

WARNING

 

Where prolonged use is foreseen, it is 

recommended a tool balancer be used. Check 

suspension device to ensure that it is secure. 

WARNING

 

Do no use tool in explosive atmosphere. 

CAUTION

 

Tool is not to be used as a hammer. 

WARNING

 

Risk of crushing exists if nose assembly is not  

attached. 

WARNING

 

It is recommended tool be operated 50 out of every 

60 minutes, where prolonged use is expected. 

WARNING 

Shock: 

 

It is recommended operator wear a suitable glove 

during operation where prolonged use is expected. 

WARNING 

Air pressure not to exceed 100 psi (6.9 bar). 

SAFETY WARNINGS 

PLEASE READ THIS MANUAL BEFORE  

SERVICING OR USING THIS TOOL.  

 

WARNINGS: 

 

MUST BE UNDERSTOOD TO AVOID 

SEVERE PERSONAL INJURY 

CAUTIONS: 

 

SHOW CONDITIONS THAT WILL 

DAMAGE EQUIPMENT OR STRUCTURE 

Summary of Contents for GB713SHA-16

Page 1: ...ILT Inc 44766 Centre Court 586 226 1500 Clinton Twp MI 48038 586 226 1505 Fax e mail solutions gagebilt com www gagebilt com GB713SHA 16 INSTALLATION TOOL GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE E MAIL US FOR A DISTRIBUTOR NEAR YOU ...

Page 2: ...equivalent Setting stroke 760 19 3mm Rated pull load GB801 series 3 500 lbs 15 6 kN GB802 series 4 500 lbs 20 0 kN Vibration Tested No Hazards Found TABLE OF CONTENTS Description Page Warnings 3 Description Operation Maintenance and Hydraulic Thread Preparation 4 Troubleshooting and Overhaul 5 Parts Lists 6 Nose Assembly Selection Chart 7 EU Conformity and Warranty 8 7 88 200mm 5 06 128 5mm 1 94 Ø...

Page 3: ...Be sure there is adequate clearance for tool and operator s hands before proceeding Keep fingers clear of any moving parts Keep fingers clear from fasteners and installed materials Severe personal injury may result CAUTION Do not use beyond the design intent WARNING Tool must be maintained in a safe working condition at all times and examined on a regular daily basis for damage or wear Any repair ...

Page 4: ...D BE AVOIDED WARNING MAINTENANCE PERSONNEL MUST READ AND UNDERSTAND ALL WARNINGS AND CAUTIONS WARNING DISCONNECT TOOL FROM ITS POWER SOURCE BEFORE PERFORMING MAINTENANCE WARNING BE SURE POWERUNIT IS DISCONNECTED BEFORE CLEANING OR WHEN REPLACING WORN OR DAMAGED COMPONENTS SEVERE PERSONAL INJURY MAY OCCUR IF POWER SOURCE IS NOT DISCONNECTED The performance of any tool depends upon the practice of g...

Page 5: ...le remove stems and reassemble c Incorrect follower OVERHAUL WARNING DISPOSE OF HYDRAULIC FLUID IN ACCORDANCE WITH ALL ENVIRONMENTAL LAWS AND REGULATIONS APPLICABLE TO YOUR AREA Service Kit 713138 contains a complete set of o rings back up rings and screws to facilitate overhaul Perform overhaul in a clean well lit area using care not to scratch or nick any smooth surface that comes in contact wit...

Page 6: ... Seal 1 6 713123 Head Cylinder Assembly 1 6A 401816 Flat Pt Set Screw 1 7 S834 O Ring 2 8 401089 Back Up Ring 1 9 200506 2 Pintail Tube 1 10 713211 Piston 1 11 A 1119 Polyseal 1 12 400793 O Ring 1 13 400808 O Ring 1 14 400824 O Ring 1 15 713217 End Cap 1 16 704113 Pintail Deflector 1 17 S832 O Ring 1 18 704129 Gasket 1 19 700324 Handle 1 20 A 663 Hanger 1 21 400061 Socket Head Cap Screw 4 22 70431...

Page 7: ...APTER 713152 STROKE LIMITER 1 INSTALLS 1 8 5 32 AND 3 16 DIAMETERS 2 ALUMINUM ONLY 3 105 P S I REQUIRED FOR MS90353 MS90354 4 THESE NOSES REQUIRE 713153 STROKE LIMITER 5 INSTALLS 5 32 3 16 AND 1 4 6CEA 751 43OS 6N 751C 54RA 4 PLEASE NOTE Due to lever assembly length the GB713SR Tools require 45 min nose length for all straight noses NOTE THE LAST 2 DIGITS OF THE NOSE ASSEMBLY REPRESENTS THE LENGTH...

Page 8: ...shipment Said warranty to remain in effect if and only if such goods are used in accordance with all instructions as to maintenance operation and use set forth in manuals and instruction sheets furnished by seller Sellers obligation under this warranty shall be limited to the repair or rework of the goods supplied or replacement thereof at Seller s option and in no case is to exceed the invoice va...