GB2581WS / GB2581AWS INSTALLATION TOOL.
TROUBLESHOOTING
Providing all maintenance conditions have been met, follow this systematic approach to diagnosis.
1. NO OPERATION WHEN ELECTRIC ACTUATOR (240122) OR AIR ACTUATOR ASSEMBLY (240123) IS DEPRESSED.
a.) Check Powerunit power source.
b.) Control cord may be loose or damaged.
c.) Faulty electric actuator. Replace.
d.) Check hydraulic couplings; repair or replace.
e.) Relief valve not installed in tool.
2. SLOW OR PARTIAL OPERATION WHEN ELECTRIC ACTUATOR (240122) OR AIR ACTUATOR ASSEMBLY (240123) IS DEPRESSED.
a.) Low hydraulic pressure. Check powerunit, adjust.
b.) Glyd Ring Assembly (406180) on Cylinder-machined (258009) could be worn or damaged. Replace.
c.) Excessive wear or scoring on moving parts. Check and replace faulty parts.
d.) Check hydraulic couplings; repair or replace.
3. TOOL OPERATES IN REVERSE.
a.) Tool stops in back position. Hydraulic hoses are reversed. Correct.
4. HYDRAULIC OIL OVERHEATS.
a.) Powerunit motor rotation reversed. Electrical connections reversed. See powerunit instruction manual.
b.) Restrictions in either hydraulic lines, hoses or couplings. Check and tighten, clean or replace. (See hydraulic thread preparation pg.10).
5. OIL LEAKAGE.
a.) Hydraulic oil leaks from connections. Tighten threaded connections. Do not use Teflon® tape. (See hydraulic thread preparation pg.10).
b.) Oil leaks from tool. Determine source of leak and replace worn or defective o'rings and back-up rings.
c.) Relief valve installed incorrectly.
6. PINTAIL GROOVES STRIPPED DURING PULL STROKE.
a.) Nose Assembly must be pushed onto fastener fully.
b.) Chips may have collected in chuck jaws. Disassemble nose assembly, clean jaws in mineral spirits using a sharp pointed object.
c.) Chuck jaws may be worn or damaged. Replace.
d.) Pintail too short for jaws to properly grip. Select proper grip length fastener.
e.) Excessive gap between sheets. Reduce gap before attempting to install fastener.
7. NOSE ASSEMBLY WON'T ACCEPT FASTENER PINTAIL.
a.) Spent fastener stem may be jammed in pulling head. Disassemble and check for worn or broken parts in nose assembly.
Replace defective parts and clean before reassembling.
8. PINTAIL OF FASTENER FAILS TO BREAK.
a.) Improper tool operation.
b.) Pull grooves on fastener stripped.
c.) Pull pressure too low.
d.) Worn relief valve.