background image

6/21 

GB128 20V BATTERY INSTALLATION TOOL

 

HOW TO USE THE GB128 

Images may not reflect actual tool or fastener 

Blind Fasteners 

Insert fastener into workpiece. 

Insert fastener into nose assembly. 

Press actuator to start cycle. 

Release actuator as soon as fastener breaks. 

5. 

Repeat steps 1-4. 

Working with the Installation tool (GB128): 

Insert the mandrel of the fastener into the nose assembly. 

Note: Tool will not function without the mandrel collection bottle (VP1002) or cover cap (VP1321) attached. 

Now insert the fastener into the parts to be fastened. For a good fastening result, ensure that the parts and head of the fastener are 

resting on one another without a gap. 

Press the actuator assy (VP1316) until the mandrel is sheared. 

Hold the installation tool so that the mandrel collection bottle (VP1002) is facing downwards to ensure that the sheared mandrel 

drops into the mandrel collection bottle (VP1002). 

When working with the cover cap (VP1321), hold the installation tool with the nose assy facing downwards after each set fastener to 

ensure that the sheared mandrel drops out of the installation tool to the front. DO NOT use cover cap (VP1321) with non self 
releasing nose assemblies. This would result in damage to the tool. 

WARNING:  

Only qualified and trained operators should install, adjust or use the installation power tool for all fasteners. 

WARNING:  

Operator 

MUST 

read and understand all warnings and cautions. 

WARNING:  

It is required that eye protection, hearing protection and safety boots be worn at all times while handling this 

equipment. 

WARNING:  

The users or the user’s employer should assess specific risks that could be present before each use based on 

their application. 

 

●  Be sure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of 

any moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.

 

 ●  

Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the 

tool

WARNING: 

Do not pull fastener in the air. Personal injury from fastener ejecting may occur.

 

WARNING:  

Do not use as a hammer.

 

If improperly used or damaged, liquid can escape from the battery causing skin 

irritations 

         or burns. Wash with water or seek medical attention immediately if liquid gets into eyes or 

burns occur.

 

WARNING:  

Do not use in explosive atmosphere.

 

WARNING:  

Charge the batteries only in chargers recommended by the manufacturer. Risk of fire or explosion if batteries 

         used on non manufacturer chargers. 

WARNING: 

Use only the specified batteries in the tool. The use of other batteries could result in injury or fire. 

WARNING:  

Keep battery (VP1086), when not in use, away from paper clips, coins, keys, nails, screws, or other small metal 

         objects that could cause bridging of the contacts. A short circuit between the battery contact can cause burns 

or fire.

 

WARNING:  

Never operate the installation tool without the mandrel collection bottle (VP1002) or cover cap (VP1321). 

WARNING:  

By-passing the safety switch is prohibited. Do not use if switch is defective or can no longer be turned on or off. 

WARNING:  

Do not use cover cap (VP1321) with non self releasing nose assemblies. Damage to tool will occur. 

WARNING:  

Ensure the mandrel collection bottle (VP1002) / cover cap (VP1321) are properly connected and used correctly. 

WARNING:  

Avoid inadvertent starting of the installation tool. 

WARNING:  

Having your finger on the actuator assy (VP1316) while carrying the installation tool can lead to accidents. 

CAUTION: 

 

Check that the hanger clip (VP1322) is securely fitted before using the tool. Ensure the clip is not stretched too  

  far apart and loses its tension. 

CAUTION: 

 

Do not use beyond the design intent. 

CAUTION: 

 

Remove the battery (VP1086) before making adjustments to the tool, changing accessories, or putting tool away. 

  This precautionary measure prevents any unintentional starting of the installation tool. 

Summary of Contents for GB128 Series

Page 1: ...IBUTOR NEAR YOU GB128 20V BATTERY INSTALLATION TOOL ORIGINAL INSTRUCTIONS 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions gagebilt com www gagebilt com GAGE BILT MADE in USA GB128 SERIES GB128 Includes 1 VP1086 2Ah Battery GB128 2 Includes 2 VP1086 2Ah Batteries ...

Page 2: ...OF CONTENTS Page Warranty 3 Description and Technical Specifications 4 Description of Functions5 Warnings 6 Principle of Operation 7 How to set up the GB128 8 10 How to use the GB128 11 Maintenance 12 Troubleshooting 13 Parts Lists 14 Accessories 16 ...

Page 3: ...nty shall be limited to the repair or rework of the goods supplied or replacement thereof at Seller s option and in no case is to exceed the invoice value of said goods Under no circumstances will the seller be liable for incidental or consequential damages or for damages incurred by the buyer or subsequent user in repairing or replacing defective goods or if the goods covered by this warranty are...

Page 4: ...put Current Ah 4 Charger Working Temp F C 32 F 104 F 0 C 40 C Charger charging time to 22 30 minutes 90 100 Charger weight w o cable 1 22 lbs 0 55 kg ENVIRONMENTAL USE WARNING Do not operate in an explosive atmosphere The GB128 can be operated between 23 F 113 F 5 C 45 C DESCRIPTION WARNING Any other use is forbidden The GB128 is a battery operated 20V cordless installation tool designed specifica...

Page 5: ...IONS Nose Tip Images may not reflect actual tool Mandrel Collection Bottle Nose Assy Actuator Assy Riveting Point Light white LED Battery Lock Release Latch Hanger Hole Battery with charging status indication Universal Quick Charger Fault Indicator Red Yellow LED ...

Page 6: ...e that fixation is secure 9 Beware of the risk of crushing or pinching if nose equipment is not fitted 10 Due to the tool weight it is recommended safety shoes be worn during operation 11 It is recommended tool be operated not more than 50 out of every 60 minutes where prolonged use is expected REPETITIVE MOTIONS HAZARDS 1 When using the tool the operator can experience discomfort in the hands arm...

Page 7: ...otor When the actuator assembly is depressed the gear on the motor spins the gear on the gear box assy retracting the nose assembly collet This action causes the jaws to clamp on the fastener pintail and pull the sheets together Further force breaks the pintail off When the actuator is released the tool moves back to its starting position The spent pintail is released and drops out the back of the...

Page 8: ...s or burns occur WARNING Do not use in explosive atmosphere WARNING Charge the batteries only in chargers recommended by the manufacturer Risk of fire or explosion if batteries used on non manufacturer chargers WARNING Use only the specified batteries in the tool The use of other batteries could result in injury or fire WARNING Keep battery VP1086 when not in use away from paper clips coins keys n...

Page 9: ...drel collection bottle VP1002 by turning to the right Note Tool will not function without mandrel collection bottle VP1002 or cover cap VP1321 attached See safety switch below 2 Screw nose assembly onto tool and wrench tighten using flats on anvil 3 Push the battery VP1086 into the foot of the installation tool from the front and ensure it is properly engaged Safety Switch This installation tool i...

Page 10: ...tuator assy VP1316 briefly and the tool moves to its starting position again HOW TO SET UP THE GB128 Cont BELT CLIP VP1322 SLOTS FOR BELT CLIP VP1322 2X SCREW Image may not reflect actual tool Attaching the Belt Clip VP1322 Note Always ensure belt clip VP1322 is secure to the installation tool before using Attach the belt clip VP1322 to the foot of the installation tool using the screw A correspon...

Page 11: ... installed materials Severe personal injury may result Ensure that there are no electrical cables gas pipes etc which can cause a hazard if damaged by the tool WARNING Do not pull fastener in the air Personal injury from fastener ejecting may occur WARNING Do not use as a hammer If improperly used or damaged liquid can escape from the battery causing skin irritations or burns Wash with water or se...

Page 12: ...an no longer be used can be returned to your dealer Disposal of Installation Tool and Quick Charger Installation tools chargers accessories and packaging s should be recycled in an eco friendly manner Do not throw tools into the domestic waste For EU countries only 1 In accordance with European Directive 2002 96 EC on Waste Electrical and Electronic Equipment and implementation in national law Ins...

Page 13: ...ing positions 2 THE INSTALLATION TOOL COMPLETES THE CYCLE THEN STOPS a The battery VP1086 is dead The tool is protected by a protection circuit The LED lights up yellow Replace the battery with a fully charged one The yellow LED goes out and you can continue working THE INSTALLATION TOOL DOESN T WORK WITH A FULLY CHARGED BATTERY a Ensure mandrel collection bottle VP1002 or cover cap VP1321 is secu...

Page 14: ...VP1375 CLAMPING SLEEVE 1 25 VP1351 PLASTIC TUBE 1 10 VP1343 FRONT SLEEVE 1 26 VP1387 MANDREL DISCHARGE TUBE 1 11a VP1344 RETENTION NOSEPIECE 6 mm 1 27 VP1002 MANDREL CONTAINER L 8 CM 1 11b VP1345 RETENTION NOSEPIECE 7 8 mm 1 28 VP1358 MANDREL SAFTEY SWITCH COVER PLATE 1 12 VP1316 TRIGGER AND PRESSURE SPRING 1 29 VP1426 MANDREL SAFTEY SWITCH LEVER SPRING 1 13 VP1317 HANGER 1 30 VP1430 MANDREL SAFTE...

Page 15: ... 6 21 GB128 20V BATTERY INSTALLATION TOOL This page intentionally left blank ...

Page 16: ...GB110A Blind rivets 3 32 2 4 mm thru 1 4 6 3 mm specific 5 16 7 9 mm diameter Lockbolts 5 32 3 9 mm thru 1 4 6 3 mm Contact Gage Bilt for nose assy options GB108 Blind rivets 3 32 2 4 mm thru 1 4 6 3 mm diameter GB116RN Rivet nuts M4 M10 M3 M12 Optional Rivet studs M4 M8 Process Monitoring GB108A Blind rivets 3 32 2 4 mm thru 1 4 6 3 mm diameter Contact Gage Bilt for nose assy options GB101S Blind...