12
•
US
Error mode
The charger enters error mode before start in the following situations:
•
The battery is connected with poles reversed to the charger's terminals.
•
The terminals on the charger are short-circuited.
Error mode before start is reset by removing the error situation. The charger restarts in
the latest selected mode.
The charger enters steady error mode in the following situations:
•
The charger’s analysis function has interrupted charging.
•
The charger is overloaded in Supply mode.
•
The charger has been in start mode longer than maximum time.
Steady error mode is acknowledged/reset by pressing the ”MODE” button. The charger
restarts in the latest selected mode.
BULK CHARGING TIME
Battery size (Ah)
Time to ~80% charge (h)
14
2
50
6–7
90
11–13
150
20–22
Recommended Minimum AWG Size for AC Extension cords
Length of cord feet (m)
AWG Size of cord
25 (7.6)
18
50 (15.2)
18
100 (30.5)
18
150 (45.6)
16
OVERHEATING PROTECTION
The MULTI US 7002 is equipped with overheating protection. In high ambient tempera-
tures the output power is reduced. Do not cover the charger.