Please  read  these  instructions  before 

installing or using this appliance for the first 
time. 

 

This  appliance  is  only  intended  for 

household use. 

 

The  installation  must  be  carried  out  in 
accordance with the current local electrical 
regulations. Any installation or reinstallation 

has  to  be  carried  out  by  an  experienced 
technician. 

 

Dielectric  bushingsmust  be  fitted  to  the 
water inflow and outlet pipes. The warranty 

will not cover damage caused by them not 
being fitted. 

 

The use of this water heater is forbidden in 
areas  where  there  are  explosive  gases  or 
flammable substances.  

 

Please  check  that  the  voltage  in  the  rating 
label fits the power supply. 

 

This appliance must be grounded. 

 

Keep  the  supply  cable  away  from  the  hot 
parts of the water heater. 

 

Improper  handling  of  the  appliance  may 

result in serious injury. 

 

Do not pull on the cable but on the plug to 

disconnect the water heater from a socket. 

 

Do not use extension leads.They can result 
in overheating and cause a fire. 

 

Never  touch  the  immersion  heater  when 
bare-footed  or  if  your  hands  are  wet  or 
damp. 

 

The water heater must be unplugged when 

it is installed and being cleaned. 

 

The  appliance  should  not  be  installed  just 

below an electrical receptacle. 

 

The  appliance  must  be  installed  in  such  a 
way that it is impossible for anyone using a 
bath or shower, to touch the controls. 

 

Keep  combustible  materials,  such  as 

furniture, pillows, bedding, papers, clothes, 
etc.  and  curtains  at  least  80cm  from  the 
front, sides and rear of the water heater. 

 

Never  dismantle  the  immersion  heater 

components  or  replace  them  with  others 
that  do  not  meet the  safety requirements.If 
the  power  cable  is  damaged,  it  must  be 
replaced  by  the  manufacturer  or  by  its 
official agent to avoid any hazard. 

 

This  appliance  can  be  used  by  children 

aged from 8 years and above and persons 
with  reduced  physical,  sensory  or  mental 
capabilities  or  lack  of  experience  and 
knowledge  if  they  have  been  given 

supervision  or  instruction  concerning  the 
use  of  the  appliance  in  a  safe  way  and 
understand the hazards involved.  

 

Children must not play with the appliance.  

 

Cleaning  and  user  maintenance  must  not 
be made by children without supervision. 

 

In  time,  the  presence  in  the  air  of  smoke, 

dust  and  pollutionmay  stain  the  walls  and 
areas close to the appliance. 

 

Do not use outdoors. 

 
 
The  symbol  on  the  product  or  in  its 
packaging  indicates  that  this  product  may 

not  be  treated  as  household 
waste.  Instead  it  shall  be  handed 
over  to  the  applicable  collection 

point  for  the  recycling  of  electrical  and 
electronic  equipment.  By  ensuring  this 
product is disposed of correctly, you will help 
prevent  potential negative consequences for 
the  environment  and  human  health,  which 
could otherwise  be  caused by inappropriate 
waste  handling  of  this  product.  For  more 
detailed  information  about  recycling  of  this 

product, please contact your local city office, 
your household waste disposal service or the 
shop  where  you  purchased  the  product. 
These  instructions  are  only  valid  in  the  EU 
member states.

 

 

 

 

Summary of Contents for GTC-30

Page 1: ...cciones Las instrucciones deben conservarse para futuras referencias Este manual debe ser conservado y dado a cualquier nuevo usuario Please read these instructions before installing or using this app...

Page 2: ...importante mantener una distancia de 80 cm entre el termo y cortinas u otros objetos inflamables Nunca desmonte los componentes del termo ni los reemplace por otros que no cumplan los requisitos de s...

Page 3: ...00 100 100 100 100 100 B 90 90 100 100 100 100 D 610 910 790 935 1305 1500 E 270 270 350 350 350 350 F 0 0 345 495 845 800 G 430 730 240 240 240 270 H 334 334 500 500 500 500 I 354 354 507 507 507 507...

Page 4: ...m s pr ximo posible al punto de utilizaci n del agua caliente con ello se evitan p rdidas de temperatura del agua en el recorrido por las tuber as Cuando se instale el termo en posici n vertical deja...

Page 5: ...uridad debe ser conectada OBLIGATORIAMENTE a una tuber a de desag e que tenga un di metro por lo menos igual al de la tuber a de conexi n del termo con una inclinaci n continuada y abierta a la atm sf...

Page 6: ...rendido entre los mismos planos horizontales se alados para el volumen de prohibici n y otros verticales situados a 1 20 metros de los del citado volumen En el volumen de PROHIBICI N no se instalar n...

Page 7: ...est instalado es recomendable vaciar el termo El vaciado se puede hacer por el drenaje de la v lvula de seguridad En todo caso Cortar la corriente Cerrar el grifo entrada agua en la instalaci n Abrir...

Page 8: ...orna de conexi n 2 Termostato y limitador t rmico 3 Resistencia 1 x 2000W 4 Piloto de funcionamiento MODELOS GTB 80 GTB 100 GTB 150 y GTB 200 1 Termostato 2 Limitador t rmico 3 Resistencias 2 x 1000W...

Page 9: ...ws bedding papers clothes etc and curtains at least 80cm from the front sides and rear of the water heater Never dismantle the immersion heater components or replace them with others that do not meet...

Page 10: ...0 B 90 90 100 100 100 100 D 610 910 790 935 1305 1500 E 270 270 350 350 350 350 F 0 0 345 495 845 800 G 430 730 240 240 240 270 H 334 334 500 500 500 500 I 354 354 507 507 507 507 K 615 915 803 948 13...

Page 11: ...d to place it as close as possible to the point where the hot water will be used this will avoid temperature losses of the water as it goes through the pipes When the immersion heater is installed ver...

Page 12: ...f the safety unit MUST be connected to a drain pipe which is at least equal in diameter to that of the immersion heater connection pipe with a continuous slope and open to the atmosphere ensuring ther...

Page 13: ...bedded in the floor PROTECTION VOLUME It is the volume situated within the horizontal planes stated for the prohibited volume plus other vertical ones 1 20 metres away from those of that volume No swi...

Page 14: ...he unit The heater should be drained if it is not to be used for extended periods of time and if there is any risk of freezing pipes at the premises where it is installed The heater can be drained usi...

Page 15: ...50 1 Connection block 2 Thermostat and thermal cut out 3 Heating element 1 x 2000W 4 Pilot lamp MODELS GTB 80 GTB 100 GTB 150 and GTB 200 1 Thermostat 2 Thermal cut out 3 Heating elements 2 x 1000W 4...

Page 16: ...19 57 14 www elnur es Como parte de la pol tica de mejora continua Elnur s a se reserva el derecho a realizar modificaciones t cnicas sin previo aviso As a part of the policy of continuous product imp...