background image

Elnur

 

powered by Gabarrón  |  ECOMBI HHR  |   Installation Guide

16

PRODUCT FICHE

Value

Item

Symbol

ECOHHR20

ECOHHR30

ECOHHR40

Unit

Heat Output 

Nominal heat output 

P

 nom

0.8

1.2

1.6

kW

Minimum heat output 

P

 min

N.A.

N.A.

N.A.

kW

Maximum continuous heat output 

P

 max, c

0.8

1.2

1.6

kW

Auxiliary electricity consumption 

 

At nominal heat output  

el

 max

0.000

0.000

0.000

kW

At minimum heat output  

el

 min

0.000

0.000

0.000

kW

In standby mode  

el

 sb

<0.0005

<0.0005

<0.0005

kW

MODEL(S): GABARRON ECOHHR20, ECOHHR30, ECOHHR40 

ErP

Item

Value. All models

Type of heat input

Electronic heat charge control with room and/or outdoor temperature feedback 

Yes

Type of heat output / room temperature control

Electronic room temperature control plus week timer  

Yes

Other control options 

 

Room temperature control, with open window detection 

Yes

With distance control option

Yes

With adaptive start control  

Yes

Contact details

ELNUR, UK  
Unit 1, Brown Street North, Leigh, Lancashire, WN7 1BU

Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric storage local  

space heaters. 

Summary of Contents for Elnur ECOMBI HHR Series

Page 1: ...ore installing or using this appliance for the first time Please read these instructions carefully before installing or using this appliance for the first time Installation Instructions ECOMBI HHR Hig...

Page 2: ...n or approved service agent before reusing Do not use the heater outdoors To disconnect the heater turn off the isolator switches and at the consumer unit Do not insert or allow foreign objects to ent...

Page 3: ...t must be replaced This heater should be switched off at the isolation switch and or circuit breaker before any repair work is carried out on the heater This appliance is only intended for a fixed ins...

Page 4: ...heater to stand on its feet and remove the carton Please check that it is the correct model and is in good condition Check that all parts have been delivered and are intact 1 ECOMBIHHR heater casing 1...

Page 5: ...ppliances are heavy it is the installers responsibility to ensure the correct installation and wall support of these devices to prevent them from overturning 6 Take off the front outlet grill by remov...

Page 6: ...ft and tilt the elements outwards being careful not to damage the insulation on the bottom of the heater and carefully place the storage bricks Arrange two levels of bricks with the flat side facing t...

Page 7: ...tly you will have no difficulty in refitting the panel Make sure the bottom edge of the inner panel is inside the front lip of the heater Please see below 14 Replace the front panel When refitting the...

Page 8: ...E POWER SUPPLY CONNECTION The Elnur ECOHHR is capable of utilising a single economy 24hr supply by using the supplied link cables 1 Use the 2 black link cables provided in the plastic bag to jumper th...

Page 9: ...omy supply or economy 24hr supply to the heater should be via a 20Amp double pole isolator switch Radial circuits Connection from the 24hr supply on peak or unrestricted supply to the heater should be...

Page 10: ...ed at this point you can release the moon button Use the and buttons to move down and up the menu options To look or change each setting press and release the moon button and then use the and buttons...

Page 11: ...y shows when pressing a key then the child lock is activated To unlock Press the and buttons normally for about three seconds or until disappears INSTALLATION INSTRUCTIONS Factory Reset Factory reset...

Page 12: ...WARNING Re setting manually must be carried out only by an experienced technician Turn off the heater at the circuit breaker Take off the front panel by removing the two screws located at the bottom...

Page 13: ...f 15192636 3 275W Balancing Element ECOHHR20 Ref 15192000 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Page 14: ...f 15192638 3 410W Balancing Element ECOHHR30 Ref 15192002 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Page 15: ...f 15192638 3 550W Balancing Element ECOHHR40 Ref 15192004 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Page 16: ...0 0005 0 0005 0 0005 kW MODEL S GABARRON ECOHHR20 ECOHHR30 ECOHHR40 ErP Item Value All models Type of heat input Electronic heat charge control with room and or outdoor temperature feedback Yes Type o...

Page 17: ...ay not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of...

Reviews: