TROUBLESHOOTING

HHR does not heat. 

Please check it is connected and switched on. 
Make sure the heater has not been covered or the air vent at the bottom of the 

heater has not been obstructed. In these cases the safety cut-out may of tripped 

and may need resetting. Please contact technical support. 

HHR does not reach set up 

temperature  

Make sure that adequate temperature is selected. Shelves above the heater  

and obstacles in front of the heater can affect the output.  
Make sure the heater is sized correctly for the room. 

ERR1 is displayed 

Ambient temperature sensor is picking up an error. Please contact technical support. 

ERR2 is displayed  

Air outlet(grille) temperature sensor is picking up an error. Please contact technical 

support.

ERR3 is displayed 

Core temperature sensor is picking up an error. Please contact technical support.

Keyboard does not respond  If display shows [- -] when pressing a key then the child lock is activated. To unlock 

Press the + and - buttons (normally for about three seconds) or until [- -] disappears.

INSTALLATION INSTRUCTIONS

Factory Reset 

Factory reset allows you to reset the heater back to its 

factory default settings. 
To Reset, turn ON the heater via the switch at the right 

side of the heater while holding down the clock buttons 

at the same time. Four horizontal blinking segments will 

appear in the display to confirm reset complete, at this 

point you can release the clock buttons. 

Factory defaults: 

 

Sun

      : Comfort Temperature  

21°C

 

Moon

  : Economic Temperature  

18°C

 

ST

       : Initial % of storage charge 

80

 

P01

      : Start time of off peak period 1 

00:00

  

P02

     : End time of off peak period 1 

07:00

  

P03

     : Start time of off peak period 2 

00:00

 

P04

     : End time of off peak period 2  

00:00

 

P05

     : Ambient sensor -5°C  

0.0

 

P06

     : Max. working hours of balancing  

 

  element  

 

5

 

P07

     : Over temperature protection °C  

2

 

P08

     : Display temp. Centigrade or Fahrenheit   : 

°C

 

Open

  : Open window detection option  

Off

Auhr   :

 Automatic winter / Summer time

Weekly program resets to 00:00 - 07:00 at 18°C,  

07:00 - 22:00 at 21°C, 22:00 - 24:00 at 18°C. 

Summary of Contents for Elnur ECOMBI HHR Series

Page 1: ...ore installing or using this appliance for the first time Please read these instructions carefully before installing or using this appliance for the first time Installation Instructions ECOMBI HHR Hig...

Page 2: ...n or approved service agent before reusing Do not use the heater outdoors To disconnect the heater turn off the isolator switches and at the consumer unit Do not insert or allow foreign objects to ent...

Page 3: ...t must be replaced This heater should be switched off at the isolation switch and or circuit breaker before any repair work is carried out on the heater This appliance is only intended for a fixed ins...

Page 4: ...heater to stand on its feet and remove the carton Please check that it is the correct model and is in good condition Check that all parts have been delivered and are intact 1 ECOMBIHHR heater casing 1...

Page 5: ...ppliances are heavy it is the installers responsibility to ensure the correct installation and wall support of these devices to prevent them from overturning 6 Take off the front outlet grill by remov...

Page 6: ...ft and tilt the elements outwards being careful not to damage the insulation on the bottom of the heater and carefully place the storage bricks Arrange two levels of bricks with the flat side facing t...

Page 7: ...tly you will have no difficulty in refitting the panel Make sure the bottom edge of the inner panel is inside the front lip of the heater Please see below 14 Replace the front panel When refitting the...

Page 8: ...E POWER SUPPLY CONNECTION The Elnur ECOHHR is capable of utilising a single economy 24hr supply by using the supplied link cables 1 Use the 2 black link cables provided in the plastic bag to jumper th...

Page 9: ...omy supply or economy 24hr supply to the heater should be via a 20Amp double pole isolator switch Radial circuits Connection from the 24hr supply on peak or unrestricted supply to the heater should be...

Page 10: ...ed at this point you can release the moon button Use the and buttons to move down and up the menu options To look or change each setting press and release the moon button and then use the and buttons...

Page 11: ...y shows when pressing a key then the child lock is activated To unlock Press the and buttons normally for about three seconds or until disappears INSTALLATION INSTRUCTIONS Factory Reset Factory reset...

Page 12: ...WARNING Re setting manually must be carried out only by an experienced technician Turn off the heater at the circuit breaker Take off the front panel by removing the two screws located at the bottom...

Page 13: ...f 15192636 3 275W Balancing Element ECOHHR20 Ref 15192000 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Page 14: ...f 15192638 3 410W Balancing Element ECOHHR30 Ref 15192002 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Page 15: ...f 15192638 3 550W Balancing Element ECOHHR40 Ref 15192004 4 160 C Cut Out Manual Limiter Ref 15190730 5 110 C Left Limiter Ref 15190725 6 140 C Right Limiter Ref 15190720 7 140 C Storage Limiter Ref 1...

Page 16: ...0 0005 0 0005 0 0005 kW MODEL S GABARRON ECOHHR20 ECOHHR30 ECOHHR40 ErP Item Value All models Type of heat input Electronic heat charge control with room and or outdoor temperature feedback Yes Type o...

Page 17: ...ay not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of...

Reviews: