background image

15 

 

 

4.- REMOTE OPERATION USING THE WIFI G-CONTROL HUB 

It is possible to control the full operation of the unit remotely with Gabarron-Elnur app or app-web. The unit must be 
connected to a Wifi G-Control Hub connected to the internet to use this feature. 
 

4.1

 To associate the unit to the G-Control Hub, the discovery mode of the hub must be activated. Press the associate button at 

the back of the Gateway for 3 seconds. An orange flashing light every second indicates association mode. 

 

 

4.2

 With the hub in association mode, press 

 on the heater for 3 seconds until the Link symbol 

is shown. 

 

 

 
 
 

You control and adjust the programming and temperatures on the SSH via the Gabarron-Elnur app. 

 

4.3

 

To disassociate the unit, a reset of the unit must be realized. See “

DEFAULT SETTING & UNIT RESET

”. When the heater 

is reset, it will remove the programming and revert back to the default settings and also disassociate from the RF network and 

G-Control Hub.  

 

5.- TROUBLESHOOTING 

 

 

ECOMBI SSH does not heat. 

Please check it is connected and switched on. 
Make sure the device is not covered or the lower air inlets are not obstructed. The LR safety limit 
may be activated; in this case it is necessary to reset it manually. Please contact technician. 

ECOMBI does not reach set up 
temperature 

Make sure that adequate temperature is selected. 
Make sure the heater is sized correctly for heat loss.

 

Err Message in display 

Please contact technician. 

Keyboard does not respond 

If the 

Lock

 message is displayed, the thermal radiator keyboard is locked. Hold

 

“+”

 and 

-

” 

buttons 

simultaneously for 3 seconds to unlock the keyboard. (See Keyboard Lock Section). 

SSH does not communicate 

with the G Control Hub. 

Check the unit is associated, the symbol 

 must be shown on the display LCD. 

For distances greater than 30 metros and 2-3 walls, associate first the closest units. Each 

unit can work as signal extender. 
If 

symbol is flashing, check the G Control Hub connexion to the network, and if any 

other device in the RF Net that could be working as signal extender has been removed. 

 

 

Summary of Contents for ECOSSH158

Page 1: ...ATION INSTRUCTIONS AND USER GUIDE ECOMBI SSH SMART STORAGE HEATER ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 Please read these instructions CAREFULLY before installing or using this appliance for the fir...

Page 2: ...ildren aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given s...

Page 3: ...tion shows any sign of damage it must be replaced This heater should be switched off at the circuit breaker before any repair work is carried out This should also be done during times of the year when...

Page 4: ...OMBI in your selected installation area Use the heater fixing holes as a template and mark the wall through the fixing holes with a pencil Drill the required holes into the wall Place the dowels and s...

Page 5: ...minal on each end of the element WARNING Steel edges can cut Next unscrew the inner panel and remove it CAUTION In the interior part of this inner panel there is a very delicate thermal insulation MIC...

Page 6: ...he insulation on the bottom of the heater 9 Place the storage bricks carefully with the flat side facing the back of the heater Arrange two row levels of bricks 10 Place the heating elements back into...

Page 7: ...other location must be carried out by an experienced technician If during reinstallation the thermal insulation shows any sign of damage it must be removed and replaced by an identical part MANUALLY R...

Page 8: ...lay will illuminate with a soft white colour After certain time if no buttons are pressed the display backlight will turn off Operating mode Button Press the key to increase different values Button Pr...

Page 9: ...age heater will maintain the temperature set point and will ignore the pre set program Standby Mode the storage heater doesn t maintain any set temperature or run any programs keeping the time setting...

Page 10: ...E SETTING After pressing when the last time interval for day 7 is flashing or after pressing in day 7 the time setting configuration starts The following is shown with the day of the week flashing Use...

Page 11: ...rams It keeps the time settings configured previously When in this mode the heater will display the current time and the icon KEYBOARD LOCK Lock Unlock During any operation mode it is possible to lock...

Page 12: ...e charge is interrupted Values 1 2 3 4 5 UP10 Degrees Celsius or Fahrenheit Values C F UP11 Open Window Detection Activation On Off UP12 Adaptive Start Control Activation On Off UP13 Kind of temperatu...

Page 13: ...is reduced by the same This behaviour adapts the consumption to the real thermal needs allowing the maximum level of energy savings at the required comfort The set up temperature is independent of th...

Page 14: ...2 00 00 UP05 Ending time off peak period 2 00 00 UP06 Charging days of the week Default Charging 7 days of the week UP07 Ambient sensor Offset 0 C UP08 Max Balance resistance working period 5 hours UP...

Page 15: ...etwork and G Control Hub 5 TROUBLESHOOTING ECOMBI SSH does not heat Please check it is connected and switched on Make sure the device is not covered or the lower air inlets are not obstructed The LR s...

Page 16: ...ured under a fully assured quality system and using environmentally friendly processes Once its useful life is finished please take the device to a recycling depot so that its components can be recycl...

Page 17: ...17 LE EMITTER LIMITER LR CUT OUT MANUALLY LIMITER LE EMITTER LIMITER LR CUT OUT MANUALLY LIMITER...

Page 18: ...200 1307W STORAGE HEATER OUTPUT 230 240 975 1062W 1300 1415W 1950 2123W 2600 2831W CHARGE PERIOD 7 6 7h 7 6 7h 7 6 7h 7 6 7h CHARGING 7 4 kWh 7 4 kWh 7 4 kWh 7 4 kWh INSULATION Class I Class I Class I...

Page 19: ...0 6 0 6 W Item Value All models Type of heat input Electronic heat charge control with room and or outdoor temperature feedback Yes Type of heat output room temperature control Electronic room temper...

Page 20: ...his product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product i...

Reviews: