19
02.2012 | G25621 | Printed in Germany
Sash bracket
Counter nut
Lock washer and O-ring
Max.
screw-in depth
25 mm
≈
20 revolutions
Adjustable eyebolt
Drive
11.3 Mounting variant: clamping ring to frame bracket
"
Align the clamping ring bores with the bores of the frame
bracket .
"
Turn in and tighten the collar screws
.
"
Tighten the clamping ring fastening screw
.
11.4 Wiring and electrical connection
"
Please observe the general safety advice on chapter „4 Technical and operational
safety“ on page 14 and chapter „10 Assembly instruction“ on page 18.
Connections to be made depending on type variant.
Important
:
The running direction of the drive can be changed by exchanging the wires (pole reversal)
‘BN’-brown and ‘BU’-blue.
Please observe the specifi cations of the particular external control unit and of the
programming device.
Note
: Reprogramming a drive or a control unit is done at your own risk and responsibility !
The drive variants S60 and S100 require an external disconnecting switch or control unit.
CC of silicone
FRNC-SIHSI FE90
2 x 0,75 mm²
(without inbuilt disconnecting switch)
CC of silicone
FRNC-SIHSI FE90
3 x 1 mm²
(with inbuilt programmable
disconnecting switch)
Communication
ELTRAL S60 / S100
ELTRAL S80 / S160
CC = connecting cable
Correct position of
cable
Bracket
Move slowly
clockwise
to the
correct position of connection
cable!