10
ekey finger scanner
Installation instructions
B-55600-13-4-6
03.2014 | 16083EE | Printed in Germany
EN
2.
Product description
2.1 Technical data
Power supply
DC 8–24 V (max. 30 V)
Power consumption
< 1 W
Temperature range
Operating temperature -20°C to +70°C
IP class
IP 54 (at the front)
Template memory
99 finger templates
Template identification
duration
1–4 s
False rejection rate (FRR)
approx. 1.4 * 10
-2
False acceptance rate (FAR)
approx. 1 * 10
-6
Life span
max. 10 million finger scans
3.
Installation
3.1 Finger scanner installation height
155 cm
The prescribed assembly height for the finger scanner is at
least 155 cm or higher!
Effective and flawless operation can only be guaranteed if
the scanner is installed at the correct height.