Global-Tek (Singapore) Pte Ltd
Page
10
Cleaning procedures:
1.
Shut off power.
2.
Open the door.
3.
Clean working tables, and scrape off wasted water into machine.
4.
Lift up overflow pipe to drain tank water.
5.
Remove scrape trays and pump intake screen, dump the residues (but not to crash,
otherwise, change in shape may result in poor straining effect) and clean the
equipment.
6.
Flush to clean the interior of the machine, thoroughly wash away all the dirt inside.
7.
Put all the straining equipment back to place.
8.
Check every upper and lower spray jets for clogging, if there is any, use a narrow pin
to clear obstruction or remove the spray arms to clean.
9.
Keep the door open to let air dry, in order to prevent mould from growing.
MAINTENANCE
a
Warning: Shut off power supply, hoist caution sign nearby, to alert anyone
NOT
to
power on.
Wash and rinse arms
Both upper and lower wash and rinse arms could be rotated freely for a few seconds
by gently swinging. Turn off the machine before testing, and remove obstruction if exists.
If the straining equipment is not in place, then the wash arms and jets may be clogged.
If happened, unload the wash arms for cleaning.
To unload the wash and rinse arms, just unlock the thumb screws, between the
bearings of both arms.
Attention: the O-ring seat of the lower wash arm should not be removed.
When unloading the upper arms, hold the arm tightly during unlocking the thumb
screw, to avoid falling down.
Both sets of upper and lower arms can be exchanged for installation.