G-Tec Pulse 1000 User Manual Download Page 3

 

 

 

 

Introduction 

This UPS is specially aimed for use with multifunction Personal Computer and it is equipped with Boost & Buck 
AVR to stabilize the wide input voltage range. 

The main features of this UPS are listed below: 

 

Microprocessor control that guarantees high reliability 

 

Built-in enhanced Boost & Buck AVR   

 

Green power function for energy saving 

 

DC start function (battery start) 

 

Auto restart during AC recovery 

 

Modem and phone line surge protection 

 

USB communication port 

 

Basic functionalities 

 

 

1. 

ON/OFF power switch 

2. 

Status indicator (green LED) 

3. 

Battery indicator (yellow LED) 

4. 

Fault indicator (red LED) 

 
 

 

 

   

  1000-1500-2000 VA 

   

 

 

 

     

  650-850 VA 

 

 
 
 

1. 

AC input and AC fuse 

2. 

Battery backup outlets 

3. 

USB communication port for 
Management Software 

4. 

Modem/phone/network surge 
protection 

5. 

Cooling fan 

 

 

         

  1500-2000 VA 

 

 

     

  1000 VA 

 

 

     

  650-850 VA 

 

 

LED indicators 

 
650-850VA 

 

 

 

 

 

 

        1000-1500-2000VA 

LED 

Alarm 

UPS status 

 

LED 

Alarm 

UPS status 

 

Off 

The main is OK and the 

UPS is operating normally 

 

 

Green 

Off 

The main is OK and the 

UPS is operating normally 

 

Beep every 10 

seconds 

Power failure occurs and 

UPS is on battery mode 

 

 

Yellow 

Beep every 10 

seconds 

Power failure occurs and 

UPS is on battery mode 

 

Beep every 

second 

Low battery 

 

 

Yellow 

Beep every 

second 

Low battery 

 

Off 

UPS is off 

 

 

Green 

Off 

UPS is off 

 

Beep continuous 

UPS fault 

 

 

Red 

Beep continuous 

UPS fault 

 

 

LED on

   

  LED off     

 LED flashing

 

Important safety instructions 

To  safely  operate  this  Uninterruptible  Power  Supply  system,  please  read  and  follow  all  instructions  carefully. 
Please read this manual thoroughly before attempting to unpack, install, or operate UPS, and keep this manual 
for further reference. 

 

This  UPS  utilizes  voltages  that  may  be  hazardous.  Do  not  attempt  to  disassemble  the  unit.  The  unit 
contains no user replaceable parts. Only authorized service personnel may perform repairs. 

 

Internal battery voltage is 12V DC, sealed, lead-acid, 6 cells. 

 

Connecting  the  UPS  to  any  other  type  of  receptacle  other  than  a  two-pole,  three-wire  grounded 
receptacle may result in shock hazard, as well as violate local electrical codes. 

 

In the event of an emergency, turn off the UPS through the switch button and disconnect the power cord 
from the AC power supply to properly disable the UPS. 

 

DO NOT allow liquids or any foreign object to enter the UPS. 

 

DO NOT place beverages or any other liquid-containing vessels inside or near the unit. 

 

This unit is intended for installation in a controlled environment (controlled temperature, indoor area free 
of  conductive  contaminants).  Avoid  installing  the  UPS  in  location  where  there  is  standing  or  running 
water, or excessive humidity. 

 

DO NOT plug the UPS input into its own output. 

 

DO NOT attach a power strip or surge suppressor to the UPS. 

 

DO  NOT  attach  non-computer-related  items,  such  as  medical  equipment,  life-support  equipment, 
microwave ovens, laser printers or vacuum cleaners to the UPS. 

 

To reduce the risk of overheating, DO NOT cover the UPS cooling vents and avoid exposing the unit to 
direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. 

 

Unplug the UPS prior to cleaning it and do not use liquid or spray detergent. 

 

DO NOT turn on the UPS if it

s damaged. 

 

DO NOT dispose of batteries in a fire as they may explode.     

 

DO NOT open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. 
It may be toxic. 

 

A battery can present a risk of electrical shock and high short circuit current. The following precautions 
should be observed when working on batteries: 

- Remove watches, rings, or any other metal objects from the hands. 

- Use tools with insulated handles. 

- Wear rubber gloves and boots. 

- Do not lay tools or metal parts on top of batteries. 

- Disconnect charging source prior to connecting or disconnecting battery terminal. 

 

Servicing of batteries should be performed or supervised only by personnel knowledgeable of batteries, 
and the required precautions should be taken. 

 

Keep out of reach of children. 

 

When replacing batteries, replace them with the same number and model. 

 

The socket-outlet shall be installed near the equipment and easily accessible. 

 

With the installation of the UPS, it should be prevented that the sum of (UPS and) the connected (load) 
leakage current exceeds 3.5mA. 

 

This  pluggable  is  a  type  A  equipment  with  battery  installed  by  the  supplier  and  is  ready  to  be  used 
directly by the user. 

 

Attention!

 Hazardous through electric shock. Also with UPS disconnected from the mains, hazardous 

voltage still may be accessible through supply from battery. First of all you have to disconnect battery/ies 
terminals when maintenance or service work inside of the UPS is necessary. 

 

Attention!

  This  is  a  category  C2  UPS  product.  In  a  residential  environment,  this  product  may  cause 

radio interference, in which case the user may be required to take additional measures.

 

 

 

PULSE 

Line Interactive UPS 

EN 

 

Summary of Contents for Pulse 1000

Page 1: ......

Page 2: ...37 105138 00G PL02...

Page 3: ...ng vessels inside or near the unit This unit is intended for installation in a controlled environment controlled temperature indoor area free of conductive contaminants Avoid installing the UPS in loc...

Page 4: ...possible to start the UPS directly by batteries supplying connected devices for some minutes Trouble shooting Use the table below to solve minor problems If any abnormal situations occur that are not...

Page 5: ...tenitori con liquidi sopra o vicino l UPS L UPS destinato a installazioni in ambienti controllati temperatura controllata al coperto e in zona priva di polveri conduttive e o contaminanti Evitare di i...

Page 6: ...di rete comunque possibile avviare l UPS da batteria alimentando per alcuni minuti le periferiche connesse Risoluzione dei problemi Utilizzare la tabella qui di seguito per risolvere i problemi di li...

Page 7: ...as Ger t oder in dessen N he stellen Dieses Ger t ist f r die Installation in einer berwachten Umgebung vorgesehen kontrollierte Temperatur Innenbereich frei von magnetischen Leitern Stellen Sie die U...

Page 8: ...n mit Strom zu versorgen Fehlerbehebung Verwenden Sie die folgende Tabelle um kleinere Probleme selbst zu beheben Wenn abnormale Situationen die oben nicht aufgef hrt sind auftreten dann wenden Sie si...

Page 9: ...ans l onduleur NE placez PAS de boissons ou tout autre r cipient liquide contenant du liquide l int rieur ou proximit de l unit Cette unit est con ue pour tre install e dans un environnement contr l t...

Page 10: ...ne de courant prolong e il est possible de d marrer l onduleur directement avec des batteries en alimentant les appareils connect s pendant quelques minutes D pannage Utilisez le tableau ci dessous po...

Page 11: ...de AC para desactivar adecuadamente el mismo NO permita que entren l quidos u objetos extra os en el SAI NO coloque bebidas ni otros recipientes que contengan l quidos dentro o cerca de la unidad Esta...

Page 12: ...o de un fallo de alimentaci n prolongado es posible arrancar el UPS directamente con bater as suministrando los dispositivos conectados durante algunos minutos Soluci n de problemas Utilice la tabla i...

Page 13: ...3 USB 4 5 1000 650 850 1500 2000 VA 1000 VA 650 850 VA LED 650 850 1000 1500 2000 LED UPS LED UPS UPS UPS 10 UPS 10 UPS UPS UPS UPS UPS LED 0 LED LED UPS UPS 12 6 UPS UPS UPS UPS UPS UPS UPS UPS UPS...

Page 14: ...ViewPower UPS ON OFF LED UPS ON OFF LED UPS LED UPS 6 UPS UPS UPS PS U UPS UPS UPS 6 UPS 650 850 1000 1500 2000 650 360 850 480 1000 00 6 1500 900 2000 1200 220 230 240 162 290 10 2 6 10 12 7 1 12 9...

Page 15: ...Green power USB 1 2 3 4 1000 1500 2000 VA 650 850 VA 6 7 8 USB 9 10 1500 2000 VA 1000 VA 650 850 VA 1500 2000 1000 650 850 650 850 1000 1500 2000 10 10 0 12 6 3 5 A C2 PULSE Line Interactive UPS RU...

Page 16: ...ViewPower 2 2 6 2 6 650 850 1000 1500 2000 650 360 850 480 1000 600 1500 900 2000 1200 220 230 240 162 290 10 2 6 10 12V 7Ah x1 12V 9Ah x1 12V 7Ah x2 12V 9 Ah x2 4 6 90 DxWxH 300 x 101 x 142 320 x 130...

Reviews: