G-Scale Graphics APTC Operation And Installation Manual Download Page 4

 

Page 4 

While holding the button down, set the desired minimum speed. Release the button to save. 
 
Program Button 
A momentary press at any time will enter program mode and cause an emergency stop if pressed while running. 
In program mode, the LED will blink the Option Code of the Parameter currently selected by the DIP switch. A 
momentary button press after the code will increment the Option Code. When the desired option has been 
reached, hold down the Program Button for about 3 seconds until the LED starts flashing rapidly, indicating the 
new option has been saved. Change more options by changing the DIP switch to the desired parameter, and re-
peat above. To exit program mode, power down and restart. 
 
LED 
Power:   

LED should be ON when power is applied. 

Diagnostics:  

LED will turn OFF while a button is pressed: Start, Stop, Dir 

 

 

 

LED will turn OFF while the Start input, or Stop input goes low (connected to common). 

Programming:  LED will turn start blinking Option Codes when the Program button is pressed. 
 

 

 

LED will flash rapidly while the Program button is held down to save the option. 

While Running ... 

Automated station stops can be done using a track mounted reed switch, and a magnet located on the locomo-
tive. When the loco passes over the reed switch, a station stop will be performed as programmed by Station Stop 
Percentage Parameter 2; i.e. it will only stop a certain percentage of the time, or with the use of two reed switch-
es, one at each end of a track, and Parameter 2 Option 6, it will run in back and forth trolley mode. 
 

Stopping the train 

A running train can be stopped automatically after running for One Lap or after a Time Period of X minutes (See 
Run Mode Parameter 3.) If a station stop reed switch in used, the train will stop at the station and wait for the next 
start command. Otherwise it will just stop wherever it is when time runs out. 
 
The train can also be stopped at any time by holding down the Stop Button. 
 

Installation 

 
Power Input 

Power input to the APTC can be any DC power source, 7-25 VDC, connected to the Vin +,- terminals. The most 
economical and best power source is an industrial power supply; e.g. the Meanwell LRS-150-24, which is rated 
for 24 VDC, 6.5 amps, and can be purchased on-line for around $19. 
 
You  can  also  use  any  train  power 
pack  with  suitable  voltage  and  cur-
rent ratings, by setting the throttle for 
up to 25 VDC max. 
 

Track Output 

Connect the “Track Out” terminals to 
the  track.  The  APTC  output  is  rated 
for up to 10 amps. Output voltage will 
be  determined  by  the  power  input 
source  and  the  speed  pot  on  the 
APTC. Voltage can be adjusted from 
0 to 100% of the power input voltage. 
To change the direction the train runs 
at  power  up,  swap  the  Track  Out 
wires. 
 

Remote Controls 
 
Remote  Start  Pushbutton 

-  Con-

nect  a  momentary  push  button,  nor-
mally  open,  across  the  Start  and 
Com terminals. Momentary contact closure initiates a start.  
 

Track Mounted Reed Switch 

- Connect this to the Stop and Com terminals to initiate an automated station stop. 

 

Motion  Detector 

- An optional PIR Motion Detector Module can be used to start the train when a visitor’s pres-

Summary of Contents for APTC

Page 1: ...ision C Updated 8 18 2021 Operation and Installation Manual G Scale Graphics 5860 Crooked Stick Dr Windsor CO 80550 970 581 3567 GScaleGraphics comcast net www GScaleGraphics net Revision A Updated 8...

Page 2: ...rolley line Use the Max Speed feature to limit speed when children are at the controls Manual speed control with user programmable momentum Automated Random Station Stops via track mounted reed switch...

Page 3: ...of the Speed Pot Emergency Stop Holding the Stop button or contact closure for more than 1 2 second at any time will initiate a quick stop Speed Pot Adjust the speed pot at any time to change the spe...

Page 4: ...each end of a track and Parameter 2 Option 6 it will run in back and forth trolley mode Stopping the train A running train can be stopped automatically after running for One Lap or after a Time Perio...

Page 5: ...when the track switch is activated by a magnet The green APTC LED will blink OFF whenever a start or stop command is received whether it is hardwired or wireless The red LED on the APTC wireless rece...

Page 6: ...rack Reed Switch Remote Start Switch Start Com Start SS 5V from APTC Com Com Stop T T Power Supply 7 25 VDC In To Track 10 Amps Max All Purpose Train Control Wiring Diagram Wireless Track Reed Switch...

Page 7: ...t train will leave the station make one lap returning to the station Option 5 can be used for Continuous Running no time out Parameter 4 Auto Start Interval Timer Sets the amount of time between autom...

Page 8: ...hing rapidly which indicates the save is complete Select the next Parameter Repeat the above as needed to view or make changes to other parameters using the DIP switch to select Exit Programming Mode...

Page 9: ...trical Power Input 7 25VDC reverse polarity protection prevents damage but will not operate Track Output Up to 10 amps Short circuit protection PWM Pulse Width Modulation 20 KHZ Control Inputs Normall...

Page 10: ...e of the power supply for 115 VAC U S Output voltage should be 24 VDC maximum for use with the G Scale Graphics Trackside R C or other Track Throttles But no adjustment should be necessary as received...

Reviews: