background image

How to Use The GSM Auto Dialler

The Auto Dialler has four independent input’s

Input 1 = 

Terminal 1 connection.  (Negatively triggered)  pulled to ground

Input 2 = 

Terminal 2 connection.  (Negatively triggered)  pulled to ground

Input 3 = 

Terminal 3 connection.  (Negatively triggered)  pulled to ground

Input 4 = 

Terminal 4 connection.  (Negatively triggered)  pulled to ground

When the inputs are triggered the 

GREEN 

LED will flash 6 times to indicate that a trigger

has been received. It will then send a text message/phone call to the five saved user
numbers.

 All inputs can be triggered independently.

 The Auto dialler will reset automatically when the triggered input is released.

We have an 8 input plug in board available on request. Please email the team at

[email protected]

Alarm Mode- Input 4 only

INPUT 4 can also be used as the alarm input where the input is not always live and it does
not auto reset like inputs 1 - 3. The alarm is only made live by sending an SMS/text
message command. This is useful for attaching things like PIR or IR Beam Sensors, when
you may only want them armed at night.

To activate this mode, send the sms/text command

#

MODE

=

2

#

This sets the unit to alarm mode

Once in alarm mode the Auto Dialler can only be triggered after you have activated the
alarm input by sending the text command as follows.

#

ALARM

=

ON

#

You will receive a text message reading “ALARM ON”

With the alarm ON, INPUT 4 will then be live and looking for a trigger. To turn off
(deactivate), the alarm, please send the text command:

#

ALARM

=

OFF

#

This will deactivate the alarm.

The input will not reset automatically after a trigger. You will need to send the text
command 

#

ALARM

=

ON

when you want it armed again.

To change back to auto mode, send the sms/text command

#

MODE

=

1

This sets the unit to auto mode - 

this is the default setting

www.gsm-activate.co.uk 

- 01273462380 - [email protected]

Page 6

Summary of Contents for AD4IN1V8

Page 1: ...2G 4G GSM Auto Dialler Speech Module Model number 2G 4G AD4IN1V8 SPEECH Page 1...

Page 2: ...back The unit is enclosed in an IP65 rated enclosure meaning that it is perfectly weathered for outside installation and has passed testing in high heats and below freezing temperatures Specification...

Page 3: ...d is downwards to the board and then lock back into place Signal Strength To help make sure that you place the unit in a suitable position you can text the unit to see how much signal strength the dia...

Page 4: ...o 1 2 07234567891 send this as a text to the simcard number in the unit for contact no 2 3 07234567867 send this as a text to the simcard number in the unit for contact no 3 4 07234567822 send this as...

Page 5: ...luding spaces for your customised message Telephone Call Alerts TheAuto Dialler can be programmed to send you a telephone call after each text alarm has been sent You will receive approximately three...

Page 6: ...here the input is not always live and it does not auto reset like inputs 1 3 The alarm is only made live by sending an SMS text message command This is useful for attaching things like PIR or IR Beam...

Page 7: ...as follows PULSE REL This will Pulse the relay for 20 seconds Auto Relay Trigger Input On The Relay can be set to automatically pulse for 17 seconds when an input has been triggered Please be aware of...

Page 8: ...will send a phone call to the users in number sequence Eg User 1 first then user 2 and so on to user 5 unless the call is acknowledged If no contact number answer the call it will text all users ALAR...

Page 9: ...which are capable of 8 Amp loads This is suitable for turning on or off electrical equipment Alternatively it can be used for resetting your alarm system The relay can be manually activated by text me...

Page 10: ...t to reply within 24 hours Monday to Friday Page 11 27 07 2023 AD Different Plug In Boards Different plug in boards are available to purchase from our website or by calling or emailing the sales team...