background image

How  to  Program  the  SMS  Text  Message

You can now change the alarm message for inputs 2, 3 & 4 to your own choosing allowing
you to know which input has been triggered.

To change the message send the text command as follows.

#

MESS1

=

YOUR MESSSAGE

The default message is - “Alarm not Acknowledged”

#

MESS2

=

YOUR MESSSAGE

The default message is - Input 2 activated

#

MESS3

=

YOUR MESSSAGE

The default message is - Input 3 activated

#

MESS4

=

YOUR MESSSAGE

The default message is - Input 4 activated

This will change the message to “Your Message”

IMPORTANT - PLEASE READ

You can only use a maximum of 19 character including spaces for your customised message.

Telephone Call Alerts

The Auto Dialler can be programmed to send you a telephone call after each text alarm has
been sent.

You will receive approximately three ring tones. The unit will then hang up automatically. This
is to prevent call charges being incurred.

To set the call alert to ON please send the text message

#

CALL

=

ON

#

The unit will relay back with “CALL ON”

If the call function has been set to ON you will receive a text message and shortly after, a
phone call.

To disarm the call alerts please send the text message

#

CALL

=

OFF

#

IMPORTANT - PLEASE READ

INPUT 1 is used with the speech module and operates differently to the other inputs.
Please see page 8 for more information

www.gsm-activate.co.uk 

- 01273462380 - [email protected]

Page 5

Summary of Contents for AD4IN1V8

Page 1: ...2G 4G GSM Auto Dialler Speech Module Model number 2G 4G AD4IN1V8 SPEECH Page 1...

Page 2: ...back The unit is enclosed in an IP65 rated enclosure meaning that it is perfectly weathered for outside installation and has passed testing in high heats and below freezing temperatures Specification...

Page 3: ...d is downwards to the board and then lock back into place Signal Strength To help make sure that you place the unit in a suitable position you can text the unit to see how much signal strength the dia...

Page 4: ...o 1 2 07234567891 send this as a text to the simcard number in the unit for contact no 2 3 07234567867 send this as a text to the simcard number in the unit for contact no 3 4 07234567822 send this as...

Page 5: ...luding spaces for your customised message Telephone Call Alerts TheAuto Dialler can be programmed to send you a telephone call after each text alarm has been sent You will receive approximately three...

Page 6: ...here the input is not always live and it does not auto reset like inputs 1 3 The alarm is only made live by sending an SMS text message command This is useful for attaching things like PIR or IR Beam...

Page 7: ...as follows PULSE REL This will Pulse the relay for 20 seconds Auto Relay Trigger Input On The Relay can be set to automatically pulse for 17 seconds when an input has been triggered Please be aware of...

Page 8: ...will send a phone call to the users in number sequence Eg User 1 first then user 2 and so on to user 5 unless the call is acknowledged If no contact number answer the call it will text all users ALAR...

Page 9: ...which are capable of 8 Amp loads This is suitable for turning on or off electrical equipment Alternatively it can be used for resetting your alarm system The relay can be manually activated by text me...

Page 10: ...t to reply within 24 hours Monday to Friday Page 11 27 07 2023 AD Different Plug In Boards Different plug in boards are available to purchase from our website or by calling or emailing the sales team...

Reviews: