background image

 

13 

USING THE GENERATOR 

 
 

-CONFINED AREAS. DO NOT SECURE THE GENERATOR WITH A CHAIN OR ROPE, AS 

THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY. 

·

Keep at least several feet of clearance on all sides to allow proper ventilation for this generator. 

·

After the engine has been running for several minutes, electrical devices may be connected to this generator. 

 

 

AC Usage 

Electrical devices running on AC current may be connected according to their wattage requirements. 

 

Rated (Running) Wattage 

 

1200 Watts Running Gas / 950 Watts Running Propane

 

Surge Wattage 

 

1750 Watts Running Gas / 1200 Watts Running Propane

 

 

The 

rated (running) wattage 

corresponds to the maximum wattage a generator can output on a continuous basis. 

 

The 

surge wattage 

corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a 

refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices 
typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement. 

 

The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself. 
To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add 
these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected 
devices exceeds the rated wattage of the generator, DO NOT connect all of the devices. Select a combination of the electrical devices that will have 
a total wattage less than or equal to the rated wattage for the generator. 

 

 

A device's rated (running) wattage should be listed somewhere on the device itself and/or in its manual. If the wattage specification for a device is not 
available, the wattage can be calculated by multiplying the Voltage requirement (120) by the Amperage drawn. 

 

Watts = Volts x Amperes 

 

Or, the wattage required by a device can be estimated by using the following chart. The chart provides only estimates and it is better to know the 
exact wattage of each electrical device to be powered by this generator. 

 

 

 

 

NOTE: 

Plug appliances into the correct outlet. Connect 

standard 120 Volt, single phase, 60 Hz loads to the 120 
Volt outlet. Connect 12 Volt, DC loads to the 12 Volt 
outlet. 

 

This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage 
equal to or less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a 
generator. 

 

 

Connect only electrical devices that are in good 
working order. Faulty devices or power cords 
present the risk of electrical shock. Immediately 
turn off and disconnect any device that 
commences to operate abnormally, sluggish or 
abruptly stops. Determine if the problem was the 
device or the rated load capacity of this generator 
has been exceeded. 

Electrical Device 

Rated (Running) Watts 

Additional Surge Watts 

air compressor (1 - 1/2 HP) 

2500 

2500 

airless sprayer (1/3 HP) 

600 

1200 

coffee maker 

1500 

computer w/17 inch monitor 

800 

deep freezer 

500 

500 

electric drill (1/2 HP) 

1000 

1000 

furnace fan blower (1/2 HP) 

800 

1300 

hot plate 

2500 

microwave oven (1000 watt) 

1000 

quartz halogen work light 

1000 

refrigerator/freezer (18 Cu. Ft.) 

800 

1600 

saw - circular (7 1/4 inch) 

1500 

1500 

stereo receiver 

450 

electric stove - single element 

1500 

sump pump 

800 

1200 

television (27 inch color) 

500 

well water pump (1/3 HP) 

1000 

2000 

window air conditioner (10000 BTU) 

1200 

2000 

window fan 

300 

600 

 

Summary of Contents for GN1750D

Page 1: ...s manual provides important information on proper operation maintenance Every effort has been made to ensure the accuracy of this manual These instructions are not meant to cover every possible condit...

Page 2: ...een poweramerica com service and follow the instructions to register online following the instructions to register online Option 2 Fill out the form on the Warranty Card include in the box and return...

Page 3: ...Generator 11 Step 1 Verify Oil Level 11 Step 2 Verify Gas Level 11 Step 3 Ground the Generator 11 STARTING THE GENERATOR 12 USING THE GENERATOR 13 AC Usage 13 DC Usage 14 SWITCHING BETWEEN GASOLINE P...

Page 4: ...en to be defective in materials or workmanship under normal use during the ONE 1 YEAR warranty period Warranty repairs or replacements will be made without charge for parts or labor Parts replaced dur...

Page 5: ...less AND may be present even if you do not see or smell gas Breathing this poison gas can lead to headaches dizziness drowsiness loss of consciousness and eventually death Usage This generator is not...

Page 6: ...oors where gasoline fumes may reach flames and or sparks ank cap Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel ank and immediately wipe it up before starting this gene...

Page 7: ...7 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Page 8: ...ere are missing items call 1 888 834 4218 Monday Friday 8 AM 5 PM EASTERN Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List DC connector wires for charging 12 Volt autom...

Page 9: ...RT DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performance and service life W...

Page 10: ...ed with the generator to the Propane Tank then connect the other end to the Gas Inlet Make sure the LPG Propane cylinder is vertical and securely positioned Step 3 Ground the Generator Ground this gen...

Page 11: ...T Use only fresh UNLEADED gasoline with an octane rating of 87 or higher Never use old and or contaminated gasoline Never use a mixture of oil and gasoline Avoid getting dirt and or water in the fuel...

Page 12: ...o snap back 7 If the engine fails to start repeat step 6 NOTE After repeated attempts to start the engine consult the troubleshooting guide before attempting again 8 Once the engine has started GRADUA...

Page 13: ...e rated wattage for the generator A device s rated running wattage should be listed somewhere on the device itself and or in its manual If the wattage specification for a device is not available the w...

Page 14: ...Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15...

Page 15: ...eck Clean X Fuel Tank Verify Gas Level X Clean X Figure 7 Recommended maintenance schedule Cleaning Generator Always try to use this generator in a cool dry place If this generator becomes dirty the e...

Page 16: ...ed every 6 months or for every 100 hours of use or when the oil has become dirty To drain the oil from generator 1 Place a bucket underneath this generator to catch oil as it drains 2 Unscrew the oil...

Page 17: ...rk plug An E7TC spark plug such as NGK BP6HS is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 020 0 028in 0 5 0 7mm See Figure 9 5 If re using the spark plug use...

Page 18: ...h No storage procedure required 1 to 2 months Fill with fresh gasoline and add gasoline stablizer 2 months to 1 year Empty the fuel tank See Emptying the Fuel Tank in the Maintenance Care section 1 ye...

Page 19: ...on Pull the starter You should see a spark Engine will not start Engine will not start Engine will not start Engine runs but there is no electrical output Generator runs but does not support all conne...

Page 20: ...20 Distributed by Green Power America LLC www Green PowerAmerica com All copyright is reserved by Green Power America LLC...

Reviews: