![G-Lab GSC-4 User Manual Download Page 27](http://html1.mh-extra.com/html/g-lab/gsc-4/gsc-4_user-manual_3073392027.webp)
26 user manual GSC_4
4.2.5 CLICK PROTECTION function
4.2.6 LOOPS SLIT function
4.2.7 FACTORY SETTINGS and memory clearing
4.2.8 USB function
4.2.9 ABOUT GSC function
To enable the CLICK PROTECTION Function, enter the MENU -> CLICK PROTECTION. The function enables
to choose the deep of the ‘fade in/out’ of the signal while switching. It is possible to set three levels:
LOW/MID/HIGH.
Controller’s effect loops and their grounding can be split in two sections. One section with first two loops
with the ability of activating the input buffer. It should be connected at the front of the amp. The input
of this section is the IN input and the output of this section is the LOOP 3 SEND out. The Second section
with last 3 loops connect to the amp’s effects loop. The input of this section is LOOP 3 RETURN in and
the output of this section is OUT output.
The sentence at the bottom left side of the display indicates the state of the loops split. If there is a “LOOPS
NOT SPLITED” message on the display it is needed to proceed as follows in order to split the loops:
Enter the MENU -> LOOPS SPLIT (ON/OFF) and select ON. The relay of the loop 3 will permanently switch
ON. The information on the main display will turn to SPLIT WILL CHANGE. Then switch off the controller.
After reconnecting the power of the controller loops will split. The display will read LOOPS SPLITTED. The
process of merging the loop proceeds in an analogous manner.
To set the Function enter the MENU -> FACTORY SETTINGS.
To clear the mentioned sections see below !!.
CLEAR PRESET – clear memory with presets and MFS functions
CLEAR SETUP DATA – clear controllers settings (back to factory settings)
FACTORY RESET (CLEAR ALL) - CLEAR PRESET and CLEAR SETUP DATA
Warning! PRESETS AND SETTINGS WILL BE LOST AFTER OPERATIONS MENTIONED ABOVE !
To set the function enter the MENU -> USB. It is possible to upgrade the firmware of the controller using
the USB function. The last version of the firmware is available at www.glab.com.pl
The firmware file should be load on the flash memory and then the flash must be connected into the
USB connector. In order to upgrade the firmware enter FIRMWARE UPGRADE in the USB settings and the
upgrade will run automatically.
This function enables to read the actual firmware version.
- PULSE – setting the SWITCH to ON will short the corresponding relay for 80ms
- MOMENTARY - setting the SWITCH to the opposite (e.g. to ON when OFF) will short the corresponding
relay for 80ms
Summary of Contents for GSC-4
Page 1: ...instrukcja obs ugi bedienungsanleitung mode d emploi user manual GUITAR SYSTEM CONTROLLER...
Page 5: ......
Page 6: ...user manual GSC_4 5 1 OVERVIEW...
Page 9: ......
Page 10: ...user manual GSC_4 9 2 BASIC OPERATION...
Page 16: ...user manual GSC_4 15 3 WORKING MODE...
Page 20: ...user manual GSC_4 19 4 PROGRAMMING MODE...
Page 28: ...user manual GSC_4 27 5 CONNECTING GSC 4 ACCESSORY...
Page 32: ......
Page 33: ......