FXA FXA501575751 Instruction Manual Download Page 9

9

tool, taking into account the working conditions
and the work to be performed. Use of the power
tool for operations different from intended could
result in a hazardous situation.

5) SERVICE

a) Have your power tool serviced by a qualified repair

person using only identical replacement parts. This
will ensure that the safety of the power tool is
maintained.

UNPACKING

This packaging contains sharp objects. Take care
when unpacking. Remove the machine, together with
the accessories supplied, from the packaging. Check
carefully to ensure that the machine is in good
condition and account for all the accessories listed in
this manual. Also make sure that all the accessories
are complete. If any parts are found to be missing, the
machine and its accessories should be returned
together in their original packaging to the retailer. Do
not throw the packaging away, keep it safe
throughout the guarantee period, then recycle if
possible, otherwise dispose of it by the proper means.
Do not let children play with empty plastic bags due
to the risk of suffocation.

COMPONENTS & CONTROLS (FIG.1)

LOCATION & GROUNDING

Before using this generator it must be prepared
correctly before use. Locate the generator on firm
level ground away from buildings or other structures
ensuring that the exhaust is not obstructed.

It is advisable to properly earth-ground your generator
before starting using a wire and a small earth stake.
Note: The wire and earth stake are not supplied with
the unit.

Earth spike and cable can be purchased at your local
camping supplies, or alternatively an earth spike can
be made, and it is suggested you get advice from a
registered electrical trades person. To make a spike
use a copper tube or copper rod 12mm diameter, a
minimum length of 200mm and with an M6 machine
screw one end. The cable used should be a maximum
length of 1 metre and a minimum of 1.0mm

2

to carry a

10amp load. The cable should be attached to the
generator at the earth point (Fig 2) and to the spike
between a flat washer and the copper with a lock
washer under the head of the M6 Machine screw in a
similar fashion to the earth point screw on the
generator.

When placing the spike into the ground the generator
must not be running and it is suggested that the spike
is pushed into the ground by at least 100mm so that it
is firm and a litre of water poured around it to ensure
good earth continuity.

CHECKING THE OIL

The generator is supplied without oil and must be
filled before first use, failure to do so will invalidate
your guarantee. Loosen the cover screws and remove
the maintenance cover.

Remove the oil filler cap and wipe the dipstick clean,
Fig 3.

Check the oil level by inserting the dipstick into the
filler neck without screwing it in. If the level is low, fill
to the top of the oil filler neck with the recommended
oil.

Use high-detergent, premium quality 4-stroke engine
oil SAE 10W-30.

Warning!

Non-detergent and 2-stroke engine oils will

damage the engine and are not recommended.

LOW OIL ALERT SYSTEM

The low oil alert system is designed to prevent engine
damage caused by an insufficient amount of oil in the
crankcase. Before the oil level in the crankcase can
fall below a safe limit, the low oil alert indicator light
turns on and the low oil alert system will automatically
shut down the engine.

CAUTION

1.

Engine ON/OFF switch

2.

Economy control switch

3.

Fuel ON/OFF tap

4.

Air filter and oil filler maintenance cover

5.

Choke lever

6.

AC socket (250v)

7.

Ground (earth) terminal

8.

Recoil starter

9.

DC socket

10. DC circuit breaker

11. Pilot light (Output)

12. Overload indicator light

13. Low Oil warning light

14. Fuel filler cap

15. Fuel tank vent tap

16. Spark plug maintenance cover

17. Exhaust

18. DC charging leads

19. Screwdriver

20. Spark plug spanner

WARNING

WARNING

Summary of Contents for FXA501575751

Page 1: ...FXA501575751 Instruction manual Original instructions GB pg 6 17 K ytt ohje Alkuper isten ohjeiden k nn s FI pg 18 29 Bruksanvisning vers ttning av originalinstruktionerna SE pg 30 41...

Page 2: ...2 2 4 1 5 17 15 14 18 19 1 6 10 6 20 2 7 12 11 13 16 4 3 8 9...

Page 3: ...3 3 7 9 5 6 8 Max oil level ON OFF RUN CHOKE 10...

Page 4: ...4 15 17 12 14 16 18 11 13 STOP...

Page 5: ...5 22 20 23 19 21...

Page 6: ...f purchase The manufacturer shall not be liable for any special exemplary direct indirect incidental or consequential loss or damage under this guarantee This guarantee is in addition to and does not...

Page 7: ...ee The engine must not be run at speeds that exceed the maximum stated on the rating plate Operating an engine at excessive speeds increases the hazard of personal injury Do not tamper with components...

Page 8: ...will reduce personal injuries c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools with your finger on the switch or plugging in power tools tha...

Page 9: ...w one end The cable used should be a maximum length of 1 metre and a minimum of 1 0mm2 to carry a 10amp load The cable should be attached to the generator at the earth point Fig 2 and to the spike bet...

Page 10: ...ngs or other structures ensuring that the exhaust is not obstructed Before starting the engine make sure that all the electrical loads are disconnected from the generator AC outlet socket Open the fue...

Page 11: ...icator light illuminates and the power to the connected appliance will be disconnected If the Red overload indicator light illuminates stop the generator and investigate the cause Before connecting an...

Page 12: ...rning Using gasoline or flammable solvent to clean the air filter can cause a fire or explosion Use only soapy water or a non flammable solvent Having first removed the side maintenance cover by remov...

Page 13: ...en ELECTRIC SYSTEM PROBLEMS Combustion chamber supplied with fuel Poor spark Pull rope sharply Clean tank Clean fuel line with dealers advice Supply fuel Open tap Spark plug dirty with carbon or wet w...

Page 14: ...designated collection points where they will be accepted on a free of charge basis Alternatively in some countries you may be able to return your products to your retailer upon the purchase of an equ...

Page 15: ...rotection at all time Item Spark plug Engine oil Air filter Fuel filter Valve clearance Fuel line Exhaust system Carburetor Cooling system Starting system Decarbon isation Fittings Fastenings Remark C...

Page 16: ...Displacement cc 99 DC output V A 12 5 Engine 4 stroke OHV Continuous operating time hrs 3 8 100 load Fuel tank capacity L 4 1 Fuel type Unleaded petrol Oil capacity L 0 75 Oil type SAE 10W 30 Ignition...

Page 17: ...ase recycle where facilities exist Check with your Local Authority or retailer for recycling advice CAUTION Hot exhaust do not touch Wear hearing protection Wear eye protection Wear respiratory protec...

Page 18: ...yksist tai vahingoista takuun aikana T m takuu tulee lis n eik vaikuta oikeuksiin joita kuluttajalla saattaa olla vuoden 1973 Tavaranmyyntilain ja siihen vuonna 1975 ja 1999 tehtyjen muutosten mukaise...

Page 19: ...t i takuun Moottoria ei saa k ytt nopeuksilla jotka ylitt v t arvokilvess annetun enimm isarvon Moottorin k ytt minen liiallisella nopeudella lis henkil vahingon vaaraa l k sittele osia jotka voivat...

Page 20: ...ukaisissa olosuhteissa v hent henkil vammoja c V lt vahinkok ynnistyksi Varmista ett kytkin on off asennossa sammutettuna ennen virran kytkemist Ty kalun kantaminen sormi kytkimell tai virran kytkemin...

Page 21: ...neraattoriin maadoituspisteest kuva 2 ja piikkiin aluslevyn ja lukkolevyllisen kuparin v liin M6 koneruuvin p n alle samalla tavalla kuin generaattorin maadoituspisteen ruuviin Kun piikki ty nnet n ma...

Page 22: ...en k yt n aloittamista Sijoita generaattori tukevalle tasaiselle alustalle et lle rakennuksista tai muista rakenteista jotta pakokaasun poisto ei esty Varmista ennen moottorin k ynnist mist ett kaikki...

Page 23: ...eseen katkeaa Jos punainen ylikuormituksen merkkivalo syttyy sammuta generaattori ja tutki h iri n syy Tutki ennen laitteen yhdist mist generaattoriin ett laite on hyv ss kunnossa eik sen s hk arvot y...

Page 24: ...siinin tai syttyv n liuottimen k ytt minen ilmansuodattimen puhdistamiseen voi aiheuttaa tulipalon tai r j hdyksen K yt vain saippuavett tai liuotinta joka ei syty Poista ensin sivussa oleva huoltokan...

Page 25: ...ONGELMAT Poltto kammiossa polttoainetta Huono kipin Ved vaijeria ter v sti Puhdista s ili Puhdista polttoainejohto j lleenmyyj n ohjeiden mukaan Lis polttoainetta Avaa hana Sytytystulppa likaantunut h...

Page 26: ...sittely uudelleenk ytt ja kierr tyst varten vie n m tuotteet nimettyihin ker yspisteisiin joihin ne hyv ksyt n ilmaiseksi Vaihtoehtoisesti joissain maissa voit palauttaa ne v hitt ismyyj llesi ostaess...

Page 27: ...Pakokaasuj rj estelm Kaasutin J hdytysj rj estelm K ynnistysj rj estelm Hiilen poistaminen Kiinnikkeet kiinnittimet Huomautus Tarkasta kunto S d k rkiv li ja puhdista Vaihda tarvittaessa Tarkasta ljy...

Page 28: ...n Cos 1 Tilavuus cc 99 Tasavirtal ht V A 12 5 Moottori 4 tahtinen OHV Jatkuvan k yt n aika tuntia 3 8 100 kuorma Polttoaines ili n tilavuus l 4 1 Polttoaineen tyyppi Lyijyt n bensiini ljyn m r l 0 75...

Page 29: ...yspisteeseen Pyyd kierr tysohjeita paikallisilta viranomaisilta tai j lleenmyyj lt HUOMIO pakokaasu on kuumaa l koske K yt kuulosuojaimia K yt suojalaseja K yt hengityssuojaa Yhdist generaattori maaha...

Page 30: ...ll och p verkar inte p n got s tt konsumentens r ttigheter i och med konsumentk plagen LAGSTADGADE R TTIGHETER Denna garanti r ett till gg till och p verkar p inget s tt dina lagstadgade r ttigheter B...

Page 31: ...tas vilket upph ver garantin Motorn f r inte k ras i hastigheter som verskrider maxfarten som anges p m rkpl ten Om motorn k rs i f r h ga hastigheter kar risken f r personskador Mixtra inte med kompo...

Page 32: ...str mbrytaren eller stoppa i kontakten medan str mbrytaren r p kar ocks skaderisken d Avl gsna skiftnycklar och inst llningsverktyg innan du s tter p elverktyget En skiftnyckel eller annat verktyg i...

Page 33: ...en belastning p 10 amp Kabeln ska f stas till generatorn vid jordpunkten bild 2 och till jordspetsen mellan en plan bricka och kopparn med en l sbricka och under huvudet p M6 maskinskruven p ett likn...

Page 34: ...nader eller andra strukturer f r att s kerst lla att avgaserna inte blockeras Innan du startar motorn s kerst ll att alla elektriska belastningar r fr nkopplade fr n generatorns v xelstr mskontakt ppn...

Page 35: ...nslutna apparaten kommer att avbrytas Om r d verbelastningsindikatorn t nds stoppa generatorn och unders k varf r Innan du ansluter en apparat till generatorn kontrollera att den r i ett bra skick och...

Page 36: ...l sningsmedel anv nds vid reng ring av luftfiltret kan det resultera i brand eller explosion Anv nd endast tv lvatten eller ett l sningsmedel som inte r brandfarligt Ta f rst bort serviceluckan p sida...

Page 37: ...RISKA SYSTEMET F rbr nnings kammaren f r br nsle D lig gnista Dra h rdare i repet Reng r br nsletanken Reng r br nsleledningen efter r d fr n terf rs ljaren H ll i bensin ppna br nslekranen T ndstifte...

Page 38: ...oporna F r korrekt bortskaffande behandling terst llning och tervinning ska du l mna dessa produkter p s rskilt avsedda uppsamlingsplatser d r de tas omhand utan kostnad I vissa l nder kan ett alterna...

Page 39: ...lspel Br nsleledning Avgassystem F rgasare Kylsystem Startsystem Dekarboniserin F sten f stanordningar Anm rkning Kontrollera tillst ndet Justera mellanrummet och reng r Byt ut om n dv ndigt Kontrolle...

Page 40: ...1 Cylindervolym cc 99 Uteffekt DC V A 12 5 Motor 4 taktare OHV Kontinuerlig drifttid timmar 3 8 100 belastning Br nsletankskapacitet L 4 1 Bensintyp Blyfri bensin Oljekapacitet L 0 75 Oljetyp SAE 10W...

Page 41: ...llsavfall tervinn p en tervinningsstation Kontrollera med din kommun eller terf rs ljare f r information om tervinning VARNING Hett avgasr r vidr r inte Anv nd h rselskydd Anv nd gonskydd Anv nd andn...

Page 42: ...42...

Page 43: ...43...

Page 44: ...ohde on olennaisten Unionin harmonisaatiolains d nt vaatimusten mukainen M let med ovanst ende deklaration r verensst mmelse med relevant unionslagstiftning om harmonisering 2006 42 EC 2014 30 EU 97 6...