Reinstall the spark plug cap on the spark plug
securely.
Reinstall the spark plug maintenance cover.
Warning!
Spark plug must be assembled firmly, or it
will become hot and may damage generator.
A loose spark plug can overheat and damage the
engine.
ENGINE OIL REPLACEMENT
Remove the side maintenance cover by removing the
2 screws, Fig 18.
Note: Drain the used oil while the engine is warm.
Warm oil drains quickly and completely.
Place a suitable container under the engine to catch
the used oil. Remove the dipstick and pour out the old
oil into the container, Fig 19.
With the engine in a horizontal position, fill to the top
of the oil filler neck with the recommended oil.
Replace the dipstick then reinstall the maintenance
cover and tighten the cover screws securely.
Note: Improper disposal of engine oil can be harmful
to the environment. If you change oil please dispose
of it properly. Put it in a sealed container and take it to
a recycling centre. Do not discard it in household
waste, dump it on the ground or pour it down a drain.
FUEL TANK FILTER (FIG 20)
After every 100 hours of running or every 6 months
the fuel tank filter should be removed and cleaned.
Remove the fuel tank filler cap and the filter, clean the
filter thoroughly using an environmentally friendly
water based degreasing agent and re-fit.
AIR FILTER
A dirty air cleaner will restrict air flow to the
carburettor. To prevent carburettor malfunction,
service the air cleaner regularly.
Warning! Using gasoline or flammable solvent to clean
the air filter can cause a fire or explosion. Use only
soapy water or a non flammable solvent.
Having first removed the side maintenance cover by
removing the 4 screws, Fig 21, loosen the nut (with a
crosshead screwdriver) and remove the cover, Fig 22.
Pull away the air cleaner housing. The filter can now
be removed, Fig 23. Wash the air filter in a solution od
household detergent and warm water, then rinse
thoroughly, or wash it in a non flammable or high flash
point solvent. Allow the air filter to dry thoroughly.
Reinstall the air filter and cleaner cover, then reinstall
the maintenance cover.
GENERAL INSPECTION AND STORAGE
Regularly check that all the fixing screws are tight.
They may vibrate loose over time.
STORAGE
If the generator is not to be used or is to be stored for
more than one month the following storage procedure
should be carried out. Drain all the fuel from the fuel
tank and the carburettor, ensure that all the fuel has
been removed. Remove the spark plug and pour
approximately one tablespoon full of clean engine oil
into the spark plug hole. With the ignition turned OFF
gently pull on the recoil starter cord several times. Re-
fit the spark plug and continue to pull the recoil starter
cord until the piston is on the compression stroke
(when resistance is felt) then stop pulling.
Store the generator in a dry well ventilated place
under a cover to prevent any dust or debris from
accumulating on the generator.
PLEASE NOTE:
If using for a caravan, motor home
or boat etc refer to the
manufacturers manual regarding
connection of a generator.
Do
NOT
connect into a house
ring main circuit.