15
TROUBLESHOOTING
The figures quoted are emission levels and are not necessarily safe working levels. Whilst there is a correlation
between the emission and exposure levels, this cannot be used reliably to determine whether or not the actual
level of exposure of the workroom, the other sources of noise etc. i.e. the number of machines and the adjacent
processes and the length of time for which an operator is exposed to the noise. Also the permissible exposure
level can vary from country. This information however, will enable the user of the machine to make a better
evaluation of the hazard and risk. The supplier recommends the use of ear protection at all time.
Item
Spark plug
Engine oil
Air filter
Fuel filter
Valve
clearance
Fuel line
Exhaust
system
Carburetor
Cooling
system
Starting
system
Decarbon-
isation
Fittings/
Fastenings
Remark
Check condition
Adjust gap and clean
Replace if required
Check oil level
Replace
Clean. Replace if required
Clean fuel cock filter
Replace if required
Check and adjust when
engine is cold
Check fuel hose for cracks or
damage. Replace if required
Check for leakage. Tighten or
replace gasket if required.
Check exhaust screen. Clean
and replace if required.
Check choke operation
Check fan damage
Check recoil starter operation
More frequently if necessary
Check all fittings and fixtures
and tighten if required
Pre-operation
check (daily)
Initial 1 month
or 20 hours
Every 3 month
or 50 hours
Every 6 month
or 100 hours
Every 12 month
or 300 hours
Summary of Contents for FXA501575750
Page 2: ...2 2 4 1 5 14 1 17 16 15 18 8 3 4 7 9 19 2 12 11 13 10 6 20 21 ...
Page 3: ...3 3 7 9 5 6 8 Max oil level 10 ON OFF RUN CHOKE ...
Page 4: ...4 15 17 12 14 16 18 11 13 STOP ...
Page 5: ...5 21 19 22 20 ...
Page 42: ...42 ...
Page 43: ...43 ...