TROUBLE-SHOOTING CHART

 

Check this list first before you call for service.

* *

 

NOTE: CALIBRATION IS EXCLUDED FROM FWE WARRANTY.

 Thermostats on all units are 

calibrated at the factory prior to shipping. Due to conditions in transit, beyond our control, occasionally units 

will need to be re-calibrated prior to use. This is a simple procedure for which instructions are given above. 

(1B, 2E)

*

 Heating element will either function or not function. Only a slight warmth indicates a problem

with the thermostat, not the element.

    PROBLEM        POSSIBLE CAUSE                              REMEDY              

TEMP

TOO

HOT

TEMP

NOT

HOT 

ENOUGH

 

NO

HEAT

AT ALL

1A] Adjustable thermostat set too high

1B] Thermostat needs re-calibrating*

2A] Opening door unnecessarily 

2B] Thermostat set too low

2C] Cord plug pulled out from outlet

2D] Fuse blown - no power to outlet 

2E] Thermostat out of calibration**

3A] Cabinet not plugged into outlet

3B] Thermostat knob at “ OFF ” 

3C] Rocker switch at “ OFF ” position

3D] Fuse Blown - no power to outlet 

3E] Thermostat needs replacing

3F] Heating element burned out*

1A] Set thermostat at a lower temperature 

      (no lower than 140°F).

1B] Loosen screw in thermostat knob and remove knob.

Adjust set screw in hollow stem with small blade screwdriver 

by turning CLOCK-WISE. 1/4 turn lowers temperature 

approximately 10°F. DO NOT REMOVE SET SCREW.

2A] Keep door closed and latched shut as much as possible. 

2B] Set thermostat at a higher temperature.

2C] Replug cord into proper outlet.

2D] Have a qualified electrician check power and fuse box.

2E] Loosen set screw in thermostat knob and remove knob. 

Adjust set screw in hollow stem with small blade screwdriver 

by turning COUNTER-CLOCKWISE. 1/4 turn raises tempera-

ture approximately 10°F. DO NOT REMOVE SET SCREW.

3A] Plug cabinet into properly grounded electrical outlet.

3B] Adjust thermostat knob to temperature

setting required.

3C] Turn switch to “ ON ” position.

3D] Have a qualified electrician check power to fuse box.

3E] Unplug cabinet from electrical source. Loosen set screw 

in thermostat knob and remove knob. Remove control panel, 

disconnect wires from terminals on thermostat, and remove 

2 screws holding thermostat to control panel. Replace 

thermostat with new one, and re-install control panel and 

thermostat knob.

3F] Unplug cart from electrical source. Remove screws 

holding heating element in place. Gently pull element away 

from back wall a few inches to expose wire connections. Dis-

connect wires, and replace element with new one. Reconnect 

wires, secure element with screws.

Summary of Contents for HLC-2W6-7H-14-DRN

Page 1: ...MOBILE SERVING STATION OPERATING INSTRUCTIONS HLC W HLC W DRN SERIES MODELS Caution Read the instructions before using the machine ...

Page 2: ... described on the following pages your cabinet will last for many years IMPORTANT Your Manufacturer Registration Card must be returned within 30 days after initial delivery to activate the warranty Properly uncrate your unit and check for any possible damage Read this Operating Manual and Instructions Review installation instructions and have your unit s properly installed Make sure all operators ...

Page 3: ...ervice you will need to provide this information The voltage and amperage of the unit are also stamped on the serial tag UNPACKING After uncrating your cabinet remove all tape and padding which held all doors shelves racks cord etc in place during shipment HLC 2W6 7H 14 DRN Shown with Optional Accessory Sneeze Guard and Paddle Latch Sneeze Guard opens for access to cleaning Detail View of Well Dra...

Page 4: ...ions with regard to adequate wiring or grounding in your building a qualified electrician should be contacted before using your cabinet DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PRONG FROM THE CORD PLUG WARNING ONLY A QUALIFIED ELECTRICIAN SHOULD ATTEMPT TO REPAIR OR REPLACE ELECTRICAL COMPONENTS OR WIRING BE SURE THAT MODEL IS UNPLUGGED FROM ELECTRICAL SOURCE BEFORE REMOVING CONT...

Page 5: ...For optimal performance keep water level at MAX WATER LEVEL Monitor the level as water evaporates over the course of service to maintain steam Stir the food occasionally so that the temperature redistributes in the pan HEATED COMPARTMENT CONTROLS The recessed control panel is equipped with an adjustable thermostat to 190 F 87 7 C for temperature selection and an operational range thermometer to sh...

Page 6: ...TES When the cycling lights goes off the unit has reached the temperature which you selected However for best results allow cabinet to full pre heat for 20 30 minutes Load with your HOT foods Plates may be heated in the cabinet before dish up but this will require extra pre heating time Adjust your pre heat time according to the size of your cabinet and the length of your transport time AVOID PUTT...

Page 7: ... you have selected As soon as the cycling light goes off unplug the cabinet and wheel to serving area Plug the cabinet into an electrical outlet at the serving location if available so that the thermostat will re activate and automatically hold your pre selected temperature HEATED BASIN TOP SERVING WELL Add HOT water until MAX WATER LEVEL See Figure 1 below is reached on the WATER BASIN For optima...

Page 8: ...the channels too should you need temporary cold storage CLEANING Keep your cabinet clean by simply wiping the interior and exterior as needed with damp cloth or sponge and a mild soapy solution NEVER USE ABRASIVES ACIDS or STRONG CLEANERS Do not flood or allow electrical parts to become wet The interior tray slide assemblies and humidifier pans are removable for easy cleaning A stainless steel cle...

Page 9: ...nob and remove knob Adjust set screw in hollow stem with small blade screwdriver by turning CLOCK WISE 1 4 turn lowers temperature approximately 10 F DO NOT REMOVE SET SCREW 2A Keep door closed and latched shut as much as possible 2B Set thermostat at a higher temperature 2C Replug cord into proper outlet 2D Have a qualified electrician check power and fuse box 2E Loosen set screw in thermostat kn...

Page 10: ...____________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________...

Page 11: ...l Environment Facilities which is warranted for a period of six 6 months This warranty is for normal usage and does not apply to any product or parts thereof that have been misused altered or where Seller s operating instructions or specific voltage is not observed nor shall this warranty apply to defective products or parts resulting from accident following date of original shipment nor extend to...

Page 12: ...without notice Printed in USA HLC WELLS_OPSMANUAL_R 18 01 FWE Parts Department www FWEparts com Order Hotline 800 222 4393 FOOD WARMING EQUIPMENT COMPANY INC COOK HOLD TRANSPORT SERVE REFRIGERATION BARS 5599 HWY 31 W Portland TN 37148 800 222 4393 815 459 7500 Fax 815 459 7989 www FWE com sales fwe com ...

Reviews: