weight and tare} should be used when communicating with a computer. It contains
information on the current modes and status of the system sufficient to compute the
gross
,
tare
and
net
and whether the scale is in
gross
or
net
mode.
F4.6 Time and Date Format
Controls the order in which time and date is printed.
F4.7 Print Format
Controls the order print data items are sent out to the port.
F4.8 Total Format
Controls the order totals items are sent out to the port.
F4.9 Weight Accumulation
Causes a running total based on displayed weight to be maintained. There are a total of
ten (10) registers that can be used to store totals. To view a current total without clearing
it or to select a new accumulation register use the
sub-total
function. To view and clear
totals use the total function. Note: You dont have to use the same total and sub-total
registers, you can total one while accumulating to another.
F5.0 Piece Weight Enable
Enables the front panel [PC WT] button. This function is used for counting. You are
given nine (9) registers in which you store weight values for single items. When a register
is selected the weight on the scale is divided by the value in the register and the number
of items is displayed. To turn this function off and return to the normal weighing mode,
set the register to 0. Note, that this counting function is limited to display resolution
and will not be as accurate as a dedicated counting scale it is provided for convenience
only. This mode must be disabled in Legal for Trade applications.
F5.1 Consecutive Number
Enables the front panel [CN] button. This allows you to view and set a consecutive
number which may be printed. It will automatically be incremented by one each time a
print is performed.
F5.2 ID Number
Enables the front panel [ID] button. This allows you to view and enter
ID
values, used
only for printing.