background image

 

8A535X03 Rev. Preliminary-00 

 

Page 5 of 17 

 

SAFETY INFORMATION 

 

NOTE 

 

This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to 
provide reasonable protection against harmful interference when the equipment is 

operated in a commercial environment.  This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction manual, can cause 
harmful interference to radio communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be required to correct the interference 
at his own expense. 
 

 

ATTENTION! 
 

Changes or Modifications not expressly approved by Futurecom Systems Group Inc. 
could void the user’s authority to operate the equipment. 

 

GENERAL SAFETY INFORMATION 

 

The following information may or may not be applicable to your product. 
In any case, precautions should always be taken when handling any electrical product. 
 

 

IMPORTANT 
 

This manual contains important safety and operating instructions, therefore keep this 
manual always on hand! 
Prior to using any product, follow all warning, safety and operating instructions written 
on the product and in the Users Manual. 

All instructions should be saved for 

reference in the future! 

 
 

ATTENTION! 
 

Always keep product dry, never expose to any kind of moisture. 

Do Not

 expose product to extreme temperatures - as found near a hot radiator or 

stove. 

Do Not

 expose product to open flames, cigarettes, etc. 

 

Precautions should be taken to avoid objects falling or liquids spilling onto product. 

Do Not

 incorporate the use of other equipment that is not recommended or sold by the 

manufacturer. The result may be the risk of fire or electric shock injury. 
Connect DC power cord to DC power source as marked on the product.

 

This product does not contain customer serviceable components therefore 

never 

disassemble the 

product. 

 

Summary of Contents for 8A535X03

Page 1: ...PAGING ON CHANNEL REPEATER OCRP Users Manual 8A535X03 Rev Preliminary 00...

Page 2: ...prior written permission of the copyright holder Futurecom Systems Group Inc reserves the right to make changes or improvements to the equipment software or specification described in this document a...

Page 3: ...OPERATION 10 OCR INSTALLATION 11 OCR PROGRAMMING 12 INTRODUCTION 12 CONNECTING AND DISCONNECTING THE OCR TO A PC 12 INSTALLING THE PROGRAMMING SOFTWARE 12 USING THE PROGRAMMING SOFTWARE FOR SETTING UP...

Page 4: ...are 6A074X01 Notes Attentions Important Throughout this manual you will see Notes Attentions and Important Their meaning is as follows NOTE A clarifying statement that expands on the text that follows...

Page 5: ...ATION The following information may or may not be applicable to your product In any case precautions should always be taken when handling any electrical product IMPORTANT This manual contains importan...

Page 6: ...ensure compliance operations at closer than this distance is not allowed RADIO OPERATOR Futurecom requires the OCR operator to ensure FCC Requirements for Radio Frequency Exposure are met The OCR out...

Page 7: ...E LIMIT r PG 4 S 1 2 EIRP 4 S 1 2 For General Population Uncontrolled Exposure S 0 2 mW cm 2 for frequency range of 30MHz 300MHz S f 1500 in mW cm 2 for frequency range of 300MHz 1500MHz f is the mini...

Page 8: ...rence that may cause undesired 2 This device must accept any interference received 1 This device may not cause harmful interference and Operation is subject to the following two conditions This device...

Page 9: ...ont panel or remotely from a System Controller The OCR operating parameters such as power output sensitivity threshold CTCSS mode of operation frequencies of operation adjacent channel spacing etc can...

Page 10: ...the programmed OCR transmit frequency same as the receive frequency The transmit frequency signal is fed to the power amplifier module where it is filtered and amplified The driver and power amplifie...

Page 11: ...gging it into the Eurocard format card cage which can accommodate up to five OCRs The DC supply wiring must be connected to nominal 27 6VDC For more information on multi channel options call the Futur...

Page 12: ...CR 2 Plug the other end of the serial cable into the serial port of the PC 3 Follow the Programming Instructions as described in the next paragraphs 4 Exit the programming software and only then unplu...

Page 13: ...The RF IN and RF OUT ports need to be connected to the corresponding multicoupling ports or to adequate power rating 50 Ohm loads or to the test equipment 3 The DC power supply needs to be turned on...

Page 14: ...and marked with DOWNLINK MAXIMUM GAIN SETTING Ensure that the correct channel is selected if the OCR is programmed with more than one channel in the Channel Data list Set the desired maximum power ou...

Page 15: ...ting and the received own RSSI is the Antenna system isolation Unkey the OCR by setting PTT to OFF Set the RSSI CAS Threshold to at least 10 dB higher than the measured own RSSI level for example if t...

Page 16: ...d to Tx Disable in the Maintenance screen The TX LED indicator is flashing when one of the synthesizers is being out of lock DC ON GREEN When on it indicates that the OCR is powered up TX ON GREEN Whe...

Page 17: ...d Frequency Stability 900 MHz 1 5ppm 0 1 ppm With Optional External Ref Generator Modulation Types Narrowband FM Voice P25 Voice and Data Channel Spacing 25 kHz 12 5 kHz Selectivity 25kHz 12 5kHz 65 5...

Reviews: