00073815.DOC, Version 1.1
32/47
The Moving-Head can be placed directly
on the stage floor or rigged in any
orientation on a truss without altering its
operation characteristics (see the
drawing).
The fixture’s base enables to be mounted
in two ways.
For overhead use (mounting height >100
cm), always install an appropriate safety
bond.
You must only use safety bonds
complying with DIN 56927, quick links
complying with DIN 56927, shackles
complying with DIN EN 1677-1 and BGV
C1 carbines. The safety bonds, quick
links, shackles and the carbines must be
sufficiently dimensioned and used
correctly in accordance with the latest
industrial safety regulations (e. g. BGV
C1, BGI 810-3).
Please note:
for overhead rigging in public or industrial areas, a series of safety instructions have to be
followed that this manual can only give in part. The operator must therefore inform himself on the current
safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Install the safety bond by inserting the quick link in the hole on the bottom of the base. Pull the safety bond
over the trussing system etc. Insert the end in the quick link and tighten the fixation screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
Screw the clamp via a M10 screw and nut onto the Omega-clamp.
Insert the quick-lock fasteners of the Omega-clamp into the respective holes
on the bottom of the device. Tighten the quick-lock fasteners fully clockwise.