background image

6

1

TES

TER

REMO

TE

2
3
4
5

6

1
2
3
4
5

8

7

8

7

6

1

TES

TER

REMO

TE

2
3
4
5

6

1
2
3
4
5

8

7

8

7

6

1

TES

TER

REMO

TE

2
3
4
5

6

1
2
3
4
5

8

7

8

7

6

1

TES

TER

REMO

TE

2
3
4
5

6

1
2
3
4
5

8

7

8

7

Short

Open

6

1

TES

TER

REMO

TE

2
3
4
5

6

1
2
3
4
5

8

7

8

7

miSS-wired.

Wiring and Display Examples for Data Cable

 · T568B Data Cable Properly Wired

Pass appears on the display indicating a properly wired cable. The pin numbers 

on the top row agree with the bottom row indicating proper continuity. 

Both the T568A and T568B wiring standards will test the same as long as the same 

standard is used on both ends of the cable

 · T568B Cross Wired Data Cable Properly Wired

The pairs cross over (transmit to receive and receive to transmit). Pass and X-over 

appear on the display and the pin numbers on the bottom row indicate the corre-

sponding cross over to the pin numbers on the top row.

 · T568B Data Cable with Split Pairs

There is a split between the pairs on pins 3-6 and 4-5. Fail and Split appear on the 

display and the pin numbers with the split will flash.

 · T568B Data Cable with a Shorted and Open Pair

Pins 1-2 are shorted and the pair on pins 7-8 is open. Short and open appear on 

the display and the pins with wiring errors will flash.  

Dash lines will appear below the shorted pins. 

Blank space will appear below the open pairs.

 · T568B Data Cable with Reversed Pair and Crossed Connection

The pair on pins 1-2 is revered and the wires on pins 5-6 are crossed at one end 

of  the cable. Fail will appear on the display indicating a defective cable. The pins 

with wiring errors will flash.  

Pins 1-2 on the top row show below pins 2-1 indicate a reversal on the orange 

pair.

Pins 5-6 on the top row show below pins 6-5 indocate a crossed connection.

Summary of Contents for 450.68C

Page 1: ...naltester RJ F to a live circuit Exposure to voltage can damage the tester Do not modify or try to repair the tester No serviceable parts are inside Do not use the tester in a wet or damp environment...

Page 2: ...on it Exposure to voltage can damage the tester If this warning appears immediately disconnect the cable from the tester J X over Appears when the tester detects a properly wired cross over cable K Op...

Page 3: ...have no twist ing on the pairs Using the Tone Generator to trace a phone line It is necessary to use the Signalprobe RJ F 1 Connect the cable under test to the RJ11 RJ12 port on the tester 2 Press the...

Page 4: ...3 4 indicate a shorted pair The blank space under pins 1 6 ndicate an open pair DATA Warning Exposure to voltage can damage the Signaltester RJ F Immediately dis connect the cable under test is Voltag...

Page 5: ...ss the Cycle button to select the desired pins Refer to sequence chart for explanation of the pin selection When tracing a cable run from the tone generator to the end of the cable applying the tone o...

Page 6: ...in numbers on the bottom row indicate the corre sponding cross over to the pin numbers on the top row T568B Data Cable with Split Pairs There is a split between the pairs on pins 3 6 and 4 5 Fail and...

Page 7: ...ers used on coax cables will prevent the tone from passing 1 Connect the cable under test to the F connector on the tester 2 Press the ON OFF button to turn on the Signaltester RJ F than press the Vid...

Page 8: ...ntinuity The cable is good and passes the test ID3 signifies that Remote Identifier number 3 is being used to terminate the cable The flashing o s on the bottom of the display indicate the tester is r...

Page 9: ...length 305m Min Cable length for split pair de tection 0 5m Max Coax cable Resistance 100 max DC Dimensions 152x61x34 Weight 230g Futech is a registered brand of Laseto NV Belgium Futech declares that...

Reviews: