background image

1

4

5
6

7

11

14

8

9

10

12

13

2

3

A

?

D

?

G

?

 

P

Q

M

?

B

?

E

?

H

?

K

?

N

?

C

?

F

?

 

I

?

 

J

?

L

?

O

?

DESCRIPTION

TESTER

1.  Video - F-connector

2.  Voice - RJ11/RJ12 Jack

3.  Data - RJ45 Jack

4.  LCD Display

5.  Data button

6.  Voice button

7.  Cycle button

8.  Video botton

9.  Tone button

10.  On/Off button

REMOTE & ID’S

11.  Voice - RJ11/RJ12 Jack

12.  Data - RJ45 jack

13.  RJ45 Remote ID (5pcs. - permit mapping 5 remote locations)

14.  F-connector Remote ID (5pcs. - permit mapping 5 remote locations)

LCD DISPLAY

A.  VOICE 

Appears when testing or toning a phone cable.

B.  DATA 

Appears when testing or toning a network cable.

C.  VIDEO 

Appears when testing or toning a coax cable.

D.  Pass 

Indicates proper wiring on cable being tested.

E.  Fail  

Indicates wiring error on cable being tested.

F.  Tone 

Appears when the tone generator is activated.

G.  Rev  

Indicated the connections on one or more pairs.  

    

is reversed at one of the cables.

H.  Short 

Indicates that two or more wires are shorted to each other

I.  Volt! 

Flashes when the tester is connected to a cable with voltage on 

    

it. Exposure to voltage can damage the tester. If this warning  

    

appears, immediately disconnect the cable from the tester.

J.  X-over 

Appears when the tester detects a properly wired cross over  

    

cable.

K.  Open 

Appears when one or more pairs are open.

L.  Battery 

Indicates low battery. When this symbol appears, results from 

    

the tester may not be reliable and the battery should be 

    

replaced immediately.

M.  Shield 

Appears when the cable being tested has a shield that is  

    

connected at both ends. The shield indicator will flash if there is  

    

a short between the shield and any wire within the cable.

N.  Split 

Appears when the tester detects the signal is split between two  

    

or more pairs.

O.  ID   

Appears when the tester detecs a Remote ID. Then number that  

    

appears correspondsto the number on the Remote ID.

P.  Wire map  (near end) - The top row of numbers display the connector pins 

    

on the tester end of the cable in numerical order. These pins are  

    

mapped to the pins shown derectly below on the bottom row of 

    

numbers.

Q.  Wire map  (remote end) - The bottom row of numbers displays the  

    

corresponding pin numbers on the remote end of the cable. 

    

Dash lines indicate shorted pins. No pin numbers indicate an  

    

open pair.

Summary of Contents for 450.68C

Page 1: ...naltester RJ F to a live circuit Exposure to voltage can damage the tester Do not modify or try to repair the tester No serviceable parts are inside Do not use the tester in a wet or damp environment...

Page 2: ...on it Exposure to voltage can damage the tester If this warning appears immediately disconnect the cable from the tester J X over Appears when the tester detects a properly wired cross over cable K Op...

Page 3: ...have no twist ing on the pairs Using the Tone Generator to trace a phone line It is necessary to use the Signalprobe RJ F 1 Connect the cable under test to the RJ11 RJ12 port on the tester 2 Press the...

Page 4: ...3 4 indicate a shorted pair The blank space under pins 1 6 ndicate an open pair DATA Warning Exposure to voltage can damage the Signaltester RJ F Immediately dis connect the cable under test is Voltag...

Page 5: ...ss the Cycle button to select the desired pins Refer to sequence chart for explanation of the pin selection When tracing a cable run from the tone generator to the end of the cable applying the tone o...

Page 6: ...in numbers on the bottom row indicate the corre sponding cross over to the pin numbers on the top row T568B Data Cable with Split Pairs There is a split between the pairs on pins 3 6 and 4 5 Fail and...

Page 7: ...ers used on coax cables will prevent the tone from passing 1 Connect the cable under test to the F connector on the tester 2 Press the ON OFF button to turn on the Signaltester RJ F than press the Vid...

Page 8: ...ntinuity The cable is good and passes the test ID3 signifies that Remote Identifier number 3 is being used to terminate the cable The flashing o s on the bottom of the display indicate the tester is r...

Page 9: ...length 305m Min Cable length for split pair de tection 0 5m Max Coax cable Resistance 100 max DC Dimensions 152x61x34 Weight 230g Futech is a registered brand of Laseto NV Belgium Futech declares that...

Reviews: