background image

VOL

UM

E /

SENSI

TIV

ITY

OFF

0

9

Signalprobe RJ-F

TEST MODE

TONE MODE

LO

LOW PITCH TONE

ALTERNATING HIGH/LOW 

PITCH TONE

WARBLING TONE

TONE MODE

HI 1

TONE MODE

HI 2

1

2

1

2

3

4

5

6

1

2

3

4

5

6

3

6

4

5

7

8

7

8

7

8

Tone will be sent through selected pins

Tone will be sent through selected pairs

Tone will be sent through all 8 pins

RJ45

Remote ID:

5 remotes

(numbered 1-5)

Remote ID

Wall Plate

Patch Panel

Tester

5.  Press ON/OFF button to turn on the tester. Press the Data button to select the 

wire test function.

6.  Interpret the results using the Wiring and Display examples for Data further 

in this manual.

 · Testing Shielded Cables 

When testing a shielded cable, the Shield indicato will appear on the display 

if the shield is connected at both ends of the cable. If the shield is shorted to a 

wire within the cable, the Shield indicator and the corresponding shorted pin 

will flash. A dash mark under the flashing pin will appear indicating a short.

Using the Tone Generator to trace a Data Cable

It is necessary to use the Signalprobe RJ-F.

1.  Connect the cable under test to the RJ45 port on the tester.

2.  Press the ON/OFF button to turn on the Signaltester RJ-F, than press the Data 

button to select the data wire test function.

3.  Press the Tone button to activate the Tone Generator.

4.  Repeatedly press the Tone button to select the desired tone. 

Refer to sequence chart for explanation of the tone selection.

5.  The connector pins the tone is being sent through will be shown on the bot-

tom of the display. Repeatedly press the Cycle button to select the desired 

pins. 

Refer to sequence chart for explanation of the pin selection.

 · When tracing a cable run from the tone generator to the end of the cable, 

applying the tone on a single pin will allow the tone to be detected at a greater 

distance from the cable.

 · When trying to locate a cable in a equipment room or patch panel, sending the 

tone through all pins or a single pair will limit the tone signal from spreaking to 

other nearby cables.

 · The tone will be loudest when the probe tip is placed directly on the wires the 

tone is being sent through at the end of the cable.

 · When sending a tone through a single pair, verification can be made by short-

ing the suspected pair. The tone will be very faint when the pair the tone is 

being sent through is shorted.

Cable Identification on installed Data Cable

The Remote IDs can be used to identify cable runs from the patch panel to a wall 

port. Each identifier has a labeled ID number. When the tester is connected to a 

cable that has an identifier attached at the other end, the tester will display the ID 

number that is marked on the identifier.

1.  Connect the numbered remote IDs to the port for each cable that needs to 

be identified.

2.  At the wiring closet or patch panel, connect the unknown cable to the RJ45 

port on the Signaltester RJ-F.

3.  Press the ON/OFF button to turn on the tester. Press the Data button to select 

the data wire test function.

4.  If the cable being tested is connected to one of the remote IDs, the display 

will indicate the number that corresponds to the remote.

 

·

the rJ45 remote idS do Not teSt the wiriNg oN the cable.oNly the remote caN 

ideNtify wiriNg faultS. the remote may Not ideNtify the cable if the cable iS 

Summary of Contents for 450.68C

Page 1: ...naltester RJ F to a live circuit Exposure to voltage can damage the tester Do not modify or try to repair the tester No serviceable parts are inside Do not use the tester in a wet or damp environment...

Page 2: ...on it Exposure to voltage can damage the tester If this warning appears immediately disconnect the cable from the tester J X over Appears when the tester detects a properly wired cross over cable K Op...

Page 3: ...have no twist ing on the pairs Using the Tone Generator to trace a phone line It is necessary to use the Signalprobe RJ F 1 Connect the cable under test to the RJ11 RJ12 port on the tester 2 Press the...

Page 4: ...3 4 indicate a shorted pair The blank space under pins 1 6 ndicate an open pair DATA Warning Exposure to voltage can damage the Signaltester RJ F Immediately dis connect the cable under test is Voltag...

Page 5: ...ss the Cycle button to select the desired pins Refer to sequence chart for explanation of the pin selection When tracing a cable run from the tone generator to the end of the cable applying the tone o...

Page 6: ...in numbers on the bottom row indicate the corre sponding cross over to the pin numbers on the top row T568B Data Cable with Split Pairs There is a split between the pairs on pins 3 6 and 4 5 Fail and...

Page 7: ...ers used on coax cables will prevent the tone from passing 1 Connect the cable under test to the F connector on the tester 2 Press the ON OFF button to turn on the Signaltester RJ F than press the Vid...

Page 8: ...ntinuity The cable is good and passes the test ID3 signifies that Remote Identifier number 3 is being used to terminate the cable The flashing o s on the bottom of the display indicate the tester is r...

Page 9: ...length 305m Min Cable length for split pair de tection 0 5m Max Coax cable Resistance 100 max DC Dimensions 152x61x34 Weight 230g Futech is a registered brand of Laseto NV Belgium Futech declares that...