66
GOV. BASIC screen 6/6
GOV. BASIC screen 5/6
From 4/6
From 5/6
Go to the menu title of GOV. BASIC screen 1/6
(14) Rev. Sensor: Revolution sensor testing
This menu is utilized to ensure that the revolution sen-
sor is functioning properly. The display for this testing
is found in: GOV BASIC 5/6.
In order to test the sensor, do NOT start the engine. In-
stead, we recommend turning the engine over by hand
or the utilization of a starter. To prevent inadvertent
ignition of the engine, do NOT use a glow plug igniter
when turning the engine over.
The numerical values on the left side of the display are
the current value. The right side of the display indicates
the maximum sensor value. The output level needs to
be more than 60% for correct governor operation. Also,
when using the backplate sensor, the signal level of
the backplate sensor varies depending on the rotation
speed (3,000 rpm or more is the detectable rotation
speed).
Go to 1/6 from any
cursor position
Go to 6/6
By the telemetry function, the number of revolutions read
by the governor sensor can be displayed on the monitor of
the transmitter. In order to be able to display, activate the
telemetry rotation sensor (SBS-01RM) on the transmitter
and set the gear ratio to 1.00.
Note:
It can not be used when the transmitter is FASSTest
12CH system.
(15) SBUS2 rpm out: RPM display on transmitter
When displaying the rpm with the telemetry function, set it to ACT.
Setting: ACT (Active) / INH (Inhibit) Initial setting: INH
(16) SBUS2 rpm Slot: RPM display on transmitter
Set the slot number of the telemetry rotation sensor registered on the
transmitter side.