(11) SenseTyp: Sensor type
Select the type of governor sensor.
Nitro (BPS-1 backplate; Magnet Type)
1:1 Magnet "1:1 Mag" (Magnet type applied to helicopter part that turns
at the same RPM as the main rotor)
HPoleEP: For Electric motors 8 poles and above
LPoleEP: For electric motors 6 poles.
(12) GOV Gain: Governor gain
Governor Gain. If the value of the Governor Gain is set too low, the
helicopter's RPM will fluctuate with collective and cyclic pitch changes.
Conversely, if the number is too high, the RPM itself will fluctuate and
surge during flight.
Setting ranges: 1 ~ 100%
Initial value: Nitro = 40%, 1:1Magn = 60%, HPoleEP= 30%, LPoleEP = 10%
(13) L Lmt. Hov / Idle : Low limit RPM
Low RPM Limit sets the minimum amount of throttle that the governor
will command during an over-speed situation. Too low of value the en-
gine could shut off or not recover power quickly enough during the next
collective movement. If the value is set too high, the governor will not
control overspeed when the rotor head is unloaded.
Use:
L Lmt. Hov: For RPMS of 700-1700
L Lmt. Idle: For RPMS of 1701-4000
Setting ranges: L Lmt. Hov =0 ~ 80%, L Lmt. Idle = 10 ~ 80%
Initial value: L Lmt. Hov = 25%, L Lmt. Idle = 45%