24
CDR-5000 Functions
[End of charging at RX/TX]
Alarm buzzer will beep as soon as the charging at TX/RX port is over without fail after detecting
"DELTA PEAK". And "FINISHED TX & RX CHARGE" screen will be shown. The red LED at TX/
RX is turned off. Charging process is now completed.
*If the "BUZZER" is set to "OFF" in the "INITIAL SETTING", there will be no alarm buzzer.
<How to return to "TX&RX DATA" screen>
Push "Data" key to move to "DX DATA"
s c r e e n f r o m " F I N I S H E D T X & R X
CHARGE" screen, then push "Data" key
again to return to "TX&RX DATA" screen.
CUTOFF BY
This shows a detected item such as bellow.
*DELTA PEAK: This message will be shown when CHARGE CUT is carried out in proper way by "DELTA PEAK".
*LOW DC 12V: This message will be shown when CHARGE CUT is carried out by the drop of a power source.
Caution: If the output voltage increases abnormally, charging will be forced to stop as
the "FINISHED TX & RX CHARGE" screen will not be shown, MODE indicator changes
from "CHARGE" to "READY" with an alarm buzzer.
[End of discharging at TX/RX]
Alarm buzzer will beep as soon as discharging at TX/RX is over. And the "FINISHED TX & RX
DISCHARGE" screen will be shown. The blue LED at TX/RX is turned off. Discharging process is
now completed.
*If the "BUZZER" is set to "OFF" in the "INITIAL SETTING", there will be no alarm buzzer.
<How to return to "TX&RX DATA" screen>
Push "Data" key to move to "DX DATA"
screen from "FINISHED TX & RX DIS-
CHARGE" screen, then push "Data" key
again to return to "TX&RX DATA" screen.