Built-in Refrigerator
Niche SMS 7/ 6 (889 mm)
Door leaves CH
Door leaves EU
max. 594
874
+
Niche
pr
ojection
top
and
bottom
Integrated CH
Integrated EU
min. 50
(420)
1
850
SMS
Appliance
CH
887
EU
873
Niche
CH
889
EU
874
min. 50
547
-
0
2
Thickness
16 – 20 mm
Thickness
16 – 24 mm
7
/6
-division
100
120
Appliance
600
Niche
605
Appliance
545
602
555
Niche
550
Appliance 548
Niche 550
Appliance 548
Niche 560 – 568
100°
100°
Detail A
Where the appliance space
measures 550 mm the out-
put data of the appliance are
also guaranteed.
Ventilation section top and
bottom min. 200 cm
2
Electrical safety (shock-hazard protection) must be
effected as part of the installation procedure.
If the power point is no longer accessible once the
appliance is in place, a current breaker must be provi-
ded on installation. Current breakers are switches with
a contact opening of at least 3 mm, including LS swit-
ches and fuses as well as contactors.