![Furuno RC18 Series User Manual Download Page 12](http://html1.mh-extra.com/html/furuno/rc18-series/rc18-series_user-manual_2350512012.webp)
RC18xx
Battery Requirements
Current /
RC1815
RC1825
RC1840
Equipment
Calculation
Amps
Amps
Amps
PP510
0.4A x 2 =
0.8
0.8
0.8
DSC-60 1.0A
=
1
DP-6 1.6A
=
1.6
AC Fail Lamp
0.3A =
0.3
0.3
0.3
Emer. Lamp
0.3A =
0.3
0.3
0.3
Felcom 15 RX
0.9A =
0.9
0.9
0.9
Felcom 15 TX
5A/2 =
2.5
2.5
2.5
IB-583
0.6A =
0.6
0.6
FS-1570 RX
0.8A =
0.8
FS-1570 TX
20A/2 =
10
FS-2570 RX
1.5A =
1.5
FS-2570 TX
35A/2 =
17.5
FS-5000 RX
3A =
3
FS-5000 TX
60A/2 =
30
FM-8500 RX
0.5A x 2 =
1
1
1
FM-8500 TX
(6.25A/2) x 2 =
6.25
6.25
6.25
Amps Per Hour
23.45
31.65
47.65
* Method used for calculation: 1/2 of the current consumption necessary for
transm the current necessary for rec current consumption of
any additional loads
3-3