4
Setting High Speed Mode
The remaining wires are
short-circuited by default for
the Normal mode. The
conversion mode can be
changed to another one by
cutting one of the wires. For
the High-Speed mode, cut
the PORT1 (ORG) as shown
at right.
Wiring Power Cable from EVC to NAVpilot-711C (TB1)
The
processor power is supplied from the Yanmar VC10 bus (ACC)
,
NOT
from
ship
’
s mains. This is done in order to synchronize the power failure status with the EVC bus.
Cable
AT06-2S-EC01-VCT-030, Furuno part # 000-193-626-10
is used.
Code
Name
Type
000-193-626-10 CONNECTOR ASSEMBLY AT06-2S-EC01-VCT-030
Cable Drawing
Extracted from
NAVpilot-700
Installation Manual:
Section 2.2.5