background image

 

Setting High Speed Mode

 

The  remaining  wires  are 
short-circuited by default for 
the  Normal  mode.  The 
conversion  mode  can  be 
changed  to  another  one  by 
cutting one of the wires. For 
the  High-Speed  mode,  cut 
the  PORT1  (ORG)  as  shown 
at right.

 

 

 

Wiring Power Cable from EVC to NAVpilot-711C (TB1) 

 

The

  processor  power  is  supplied  from  the  Yanmar  VC10  bus  (ACC)

NOT

  from 

ship

s mains. This is done in order to synchronize the power failure status with the EVC bus. 

Cable 

AT06-2S-EC01-VCT-030, Furuno part # 000-193-626-10

 is used. 

 

 

 

Code 

Name 

Type 

000-193-626-10  CONNECTOR ASSEMBLY  AT06-2S-EC01-VCT-030 

 
Cable Drawing 
 

 

Extracted from 

NAVpilot-700 

Installation Manual: 

Section 2.2.5 