3-4
3.2 Heading
Adjustment
When the BOW mark on the flange of the hull unit cannot be directed toward ship’s bow,
adjust the heading so an echo which is dead ahead appears dead ahead on the display.
1. Referring to the previous section, set the TX (transmission) to ON.
2. Locate a target in the bow direction (buoy, for example) and display it on a near range. If
the target appears at 12 o’clock the heading alignment is correct. If it does not, measure
the error and go to next step.
Buoy
If target's on-screen
position is right of ship's
bow for example, heading
is skewed left.
Heading adjustment
3. Turn off the power and then turn it on again while pressing and holding down the
[MENU] key. Release the [MENU] key after the self-test screen appears. After the picture
appears, press the [MENU] key three times to open the SYSTEM menu.
QUIT
INTERFACE SETTING...
EXT DATA SETTING...
OWN SHIP MARK...
TEST&INITIALIZATION...
TX/RX SETTING...
TX/RX SETTING-H...
TX/RX SETTING-V...
OTHERS...
SYSTEM MENU
SYSTEM menu
4. Use the trackball to choose OTHERS and press the [MENU] key.
5. Choose HEADING ADJUST1 and press the [MENU] key.
Summary of Contents for FSV-84
Page 1: ...COLOR SCANNING SONAR FSV 84 www furuno co jp ...
Page 28: ...1 20 This page intentionally left blank ...
Page 48: ...2 20 This page intentionally left blank ...
Page 76: ...A 23 ...
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ...Nov 22 06 T Matsuguchi ...
Page 87: ...Nov 22 06T Matsuguchi ...
Page 88: ......
Page 89: ...D 16 ...
Page 90: ......
Page 91: ...Mar 14 07 R Esumi ...