2-13
Synchronizing with echo sounder or other sonar
To synchronize the transmission of the FSV-84 with an echo sounder or other type of sonar,
make connections as shown below.
•
Current driven KP input
PROCESSOR
UNIT
Echosounder
Sonar
EXT-KP
EXT-KP-IN-H
EXT-KP-IN-C
8
9
KP signal
•
Voltage driven KP input
PROCESSOR
UNIT
Echosounder
Sonar
EXT-KP
EXT-12VKP-IN
GND
10
7
KP signal
For KP sync with external echosounder/sonar make the following connections.
•
Voltage driven KP output
Processor
unit
E/S
Sonar
Current
indicator
EXT-KP
INTKP1
GND
1
2
INTKP2
GND
3
4
INTKP3
GND
5
6
KP signal
Menu setting
See EXT KP INPUT and EXT KP OUTPUT on the SYSTEM MENU/INTERFACE SETTING