3. MAINTENANCE & TROUBLESHOOTING
3-4
3.3.2
Advanced troubleshooting
This paragraph provides troubleshooting procedures for the service technician.
Table 3-3 Advanced troubleshooting
Problem
Check point
Remedy
POWER key pressed but…
control panel
does not light
•
Fuse.
•
Battery.
•
FIL board.
•
POWER board.
Measure input voltage between #1(+)
and #2(-) terminals of J1301 on the
POWER board.
12 V set: 10.2 to 20.3 V
24/32 V set: 20.4 to 41.6 V.
nothing appears
on the display
•
Brilliance setting.
•
CRT.
•
CRT voltage.
•
CRT board.
Check CRT heater. If lit, CRT is normal.
On the CRT board, adjust CONTRAST
pot. VR101 and BRIGHTNESS pot.
VR204.
WARNING
A residual charge remains in capacitors
and other devices several minutes after
turning off the power. Therefore, wait
at least 3 minutes to allow residual
charge to subside before accessing the
inside of the equipment.