4. GROUNDING AND RF PROTECTION
4-14
4.9
Separate Ground Cable
4.9.1
Ground cable – construction
When dealing with electrical installations in a marine environment, all wiring must be
done with double insulated, tinned, high quality and if exposed also UV resistant ca-
bles. This shall also apply to the separate ground cable mentioned in the previous
paragraphs.
The ground cable is constructed using an appropriate cable with a cross section area
of at least 6 mm
2
(AWG9) and terminated with insulated ring crimp terminals – see
illustration below. The crimp terminals must be a marine approved type e.g. the Du-
raSeal series from Raychem.
Antenna Unit:
M10 Insulated Ring Terminal
(Raychem, DuraSeal Series)
Communication Unit:
M4 Insulated Ring Terminal
(Raychem, DuraSeal Series)
Summary of Contents for FELCOM251
Page 9: ...EQUIPMENT LISTS viii This page is intentionally left blank...
Page 53: ...3 CONNECTING POWER 3 6 This page is intentionally left blank...
Page 85: ...6 STARTING UP THE SYSTEM 6 6 This page is intentionally left blank...
Page 89: ...7 TROUBLESHOOTING 7 4 This page is intentionally left blank...
Page 107: ...D 1 31 Jan 2020 H MAKI...
Page 108: ...4 Feb 2020 H MAKI D 2...
Page 109: ...D 3 29 Jan 2019 H MAKI...
Page 110: ...D 4 31 Jan 2020 H MAKI...
Page 111: ...D 5 18 Feb 2019 H MAKI...
Page 112: ...D 6 18 Feb 2019 H MAKI...
Page 113: ...D 7 25 Sep 2018 H MAKI...
Page 114: ...D 8 12 Dec 2018 H MAKI...
Page 115: ...D 9 10 Sep 2019 H MAKI...
Page 116: ...D 10 10 Sep 2019 H MAKI...
Page 117: ...5 Aug 2013 H MAKI D 11...
Page 118: ...16 Jul 2014 H MAKI D 12...
Page 119: ...D 13 21 Apr 2017 H MAKI...
Page 120: ...D 14 31 Jan 2019 H MAKI...
Page 121: ...D 15 31 Jan 2019 H MAKI...