19
3.
CHANGING POWER SPECIFICA-
TIONS
This unit is set at factory to operate from 220-230 VAC ship's mains. For connection
to a 100 VAC, 110-115 VAC, 200 VAC or 24 VDC ship's mains, modify the connec-
tions in the distribution box as shown below.
Note:
Tick the appropriate box on the inside of the FE-702 distribution box cover to
denote the power use.
Label inside the distribution box FE-702
100 VAC, 110-115 VAC, 200 VAC Ship's Mains
1. Connect the power cable to #1 & #3 on TB5 in the distribution box.
2. Modify the wiring at TB7 according to ship's mains as shown in the table below.
Ship's mains
TB7 #1
TB7 #2
TB7 #3
TB7 #4
TB7 #5
220-230 VAC
(Default)
Orange
Red
Black
Brown
White
200 VAC
Red
Orange
Black
Brown
White
110-115 VAC
Black
Red
Orange
Brown
White
100VAC
Brown
Red
Black
Orange
White
200-230 VAC (50/60 Hz)
100-115 VAC (50/60 Hz)
24 VDC