4. INSTALLATION
35
Optional equipment
* WIth ACCU-FISH
TM
, bottom discrimination display support.
4.2
Display Unit
Mounting considerations
The display unit can be installed on a desktop,
or flush mounted in a console. When choos-
ing a location keep the following in mind:
Name
Type
Code No.
Remarks
Transducer
520-5PSD*
000-015-204
Thru-hull mount, plastic
520-5MSD*
000-015-212
Thru-hull mount, metal
520-PLD*
000-177-684-10
Thru-hull mount, plastic
525-5PWD*
000-146-966-01
Transom mount, plastic
Triducer (trans-
ducer with speed/
temperature sen-
sor)
525T-PWD*
000-177-688-10
Transom mount, plastic
525T-BSD*
000-177-685-10
Thru-hull mount, metal
525STID-MSD*
000-011-783
Thru-hull mount, metal
525STID-PWD* 000-011-784
Transom mount, plastic
525T-LTD/12*
000-177-686-10
Tilt angle 12°, thru-hull mount, metal
525T-LTD/20*
000-177-687-10
Tilt angle 20°, thru-hull mount, metal
SS60-SLTD/12* 000-177-690-10
Tilt angle 12°, thru-hull mount, alloy
SS60-SLTD/20* 000-177-691-10
Tilt angle 20°, thru-hull mount, alloy
Converter Cable
Assy.
02S4147-1
000-141-082
Speed sensor, Speed/ Temperature sen-
sor
Cable Assy.
KON-004-02M
001-090-910
2 m
Speed/ Tem-
perature Sensor
ST-02MSB
000-137-986-01
Thru-hull mount, metal
ST-02PSB
000-137-987-01
Thru-hull mount, plastic
Temperature
Sensor
T-04MSB
000-026-893
Thru-hull mount
T-04MTB
000-026-894
Transom mount
Inside Hull Kit S
22S0191-2
000-802-598
w/installation instructions, not available
with bottom discrimination display.
Matching Box
MB-1100
000-041-353
For FCV-587, connection to 1 kW trans-
ducer
Transducer (for
FCV-587)
50B-6
000-015-042
10 m, 1 kW
50B-6B
000-015-043
15 m, 1 kW
200B-5S
000-015-029
10 m, 1 kW
50/200-1T*
000-015-170
10 m, 1 kW
50/200-12M*
000-015-171
10 m, 1 kW
Triducer (for
FCV-587)
526TID-HDD*
000-177-689-10
Thru-hull mount, metal, 1 kW (Not re-
quired Matching Box MB-1100.)
• Locate the unit away from the air from air
conditioners.
• The operating temperature range is 5°F to
131°F.
• Locate the unit away from devices that emit
active gas.
• The mounting location must be well ventilat-
ed.
• Select a location where vibration and shock
are minimal.
• Select a location out of direct sunlight. Pro-
longed exposure to direct sunlight can
cause LCD blackout.
• A magnetic compass will be affected if the
display unit is placed too close to the com-
pass. Observe the compass safe distances
in the safety instructions to prevent distur-
bance to the compass.
Summary of Contents for FCV-587
Page 1: ......
Page 73: ...7 Nov 2013 H MAKI D 1...
Page 74: ...18 Nov 2013 H MAKI D 2...
Page 75: ...D 3 13 Jan 2012 Y NISHIYAMA...
Page 76: ...D 4 13 Jan 2012 Y NISHIYAMA...
Page 77: ...D 5 12 Mar 2015 H MAKI...
Page 82: ......
Page 83: ......