4
2.2
Cable Fabrication
Power cable
This echo sounder is designed to be powered with 12-24 VDC. Use the cable DPYCY-1.5 (Japan
Industry Standard) or equivalent.
Transducer cable
Separate the transducer cable well away from power cables to prevent interference. Connect the
cable to the transducer port (for high frequency and/or low frequency) at the rear of the display
unit. Fabricate the cable as below.
Approx. 70
3
Armor
Sheath
Vinyl tape
6
Clamp armor with cable clamp.
Crimp-on lug
FV2-M4
30
Sheath
Conductor
S = 1.5 mm
Ǟ
= 1.56 mm
(AWG16)
2
DPYCY-1.5
Armor
Sheath
Ǟ
=
13.7 mm
Shield
Vinyl tape
Sheath
Wrap shield around sheath 30 mm and cut
excess shield. Clamp here with cable clamp.
Extract cores from here and cut inner materials.
Approx. 100
Attach WAGO
connector.
(See next page.)
[Composite transducer]
BLK, RED: L side
BLU, GRN: H side
Note: Never connect the shield to #2 of
the WAGO connector.
Shield
30
6
Vinyl tape