17
-4
37
-0
2 re
v.
0
1
05
/28
/14
Thru-Hull, Analog
High-Precision Temperature Sensor
Model
T42
Tools & Materials
Safety goggles
Dust mask
Electric drill
Drill bit/hole saw/spade bit:
Pilot hole
3mm
or
1/8"
T42
22mm
or
7/8"
Sandpaper
Mild household detergent
or
weak solvent (alcohol)
Marine sealant (suitable for below waterline)
Slip-joint pliers
Installation in a cored fiberglass hull (see page 2)
Hole saw for hull interior:
30mm
or
1-1/4"
Cylinder, wax, tape, and casting epoxy
Water-based anti-fouling paint (
mandatory in salt water
)
Sensor Installation
Hole Drilling
Cored fiberglass hull
—Follow separate instructions on page 2.
1. Drill a 3mm or 1/8" pilot hole from inside the hull. If there is a rib,
strut, or other hull irregularity near the selected mounting
location, drill from the outside.
2. Using the appropriate drill bit, cut a hole perpendicular to the
hull from outside the boat.
3. Sand and clean the area around the hole, inside and outside, to
ensure that the marine sealant will adhere properly to the hull. If
there is any petroleum residue inside the hull, remove it with
either mild household detergent or a weak solvent (alcohol)
before sanding.
Record the information found on the cable tag for future reference.
Part No._________________Date___________
Follow the precautions below for optimal
product performance and to reduce the risk of
property damage, personal injury, and/or death.
WARNING
: Always wear safety goggles and a dust
mask when installing.
WARNING
: Immediately check for leaks when the
boat is placed in the water. Do not leave the boat
unchecked for more than three hours. Even a small
leak can allow considerable water to accumulate.
CAUTION
: Never install a bronze sensor in a metal
hull because electrolytic corrosion will occur.
CAUTION
: Never install a metal sensor on a vessel
with a positive ground system.
CAUTION
: Never pull, carry, or hold the sensor by its
cable; this may sever internal connections.
CAUTION
: Never use solvents. Cleaner, fuel, sealant,
paint, and other products may contain solvents that can
damage plastic parts, especially the sensor’s face.
IMPORTANT
:
Read the instructions completely
before proceeding with the installation. These
instructions supersede any other instructions in your
instrument manual if they differ.
T42
INSTALLATION INSTRUCTIONS
OWNER’S GUIDE &
Applications
• Bronze sensor recommended for fiberglass or wood hull only.
• The hull must be a minimum of 8mm (5/16") thick at the
mounting location.
Mounting Location
Choose a location where the temperature sensor will be in contact
with the water at all times.
AP-6
Summary of Contents for FCV-1200L
Page 5: ...iii SYSTEM CONFIGURATION Standard type ...
Page 6: ...iv Blackbox type ...
Page 22: ...This page is intentionally left blank ...
Page 32: ...1 10 This page is intentionally left blank ...
Page 34: ...2 2 Blackbox type FCV 1200L Figure 2 2 Wiring diagram for blackbox type FCV 1200L ...
Page 35: ...2 3 Standard type FCV 1200LM Figure 2 3 Wiring diagram for standard type FCV 1200LM ...
Page 36: ...2 4 Blackbox type FCV 1200LM Figure 2 4 Wiring diagram for blackbox type FCV 1200LM ...
Page 66: ...3 24 This page is intentionally left blank ...
Page 83: ...D 1 ...
Page 84: ...D 2 ...
Page 85: ...D 2A ...
Page 86: ...D 2B ...
Page 87: ...D 3 ...
Page 88: ...D 4 ...
Page 89: ...D 5 ...
Page 90: ...D 5A ...
Page 91: ...D 5B ...
Page 92: ...Y Hatai D 6 ...
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ...Nov 14 02 D 9 ...
Page 98: ......
Page 99: ......
Page 100: ...D 12 ...
Page 102: ...S 2 ...
Page 103: ...S 3 ...
Page 104: ...S 4 ...