2. WIRING
2-4
2.3
Unit Interconnection
The transponder unit (FA-1701), monitor unit (FA-1702) and the pilot plug unit (FA-
1703) use different connectors for interconnection. See the figures below to fabricate
the connections.
How to attach wires to the connectors
Monitor unit FA-1702
Terminal opener is located inside cable clamp (rear cover).
Transponder unit FA-1701
Terminal opener is located on rear of the FA-1701 cover.
Procedure
1. Twist the cores.
2. Push the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
Terminal
opener
Push
Push
Procedure
1. Twist core.
2. Insert terminal opener and push.
3. Insert wire into hole. Be careful not to pinch the sheath.
4. Release terminal opener.
5. Pull wire to confirm it is correctly inserted.
Pilot plug unit FA-1703
Use a flat head screwdriver to open the terminals.
Procedure
1. Twist core.
2. Using a flat screw driver, push the terminal opener.
3. Insert wire into hole. Be careful not to pinch the sheath.
4. Release terminal opener.
5. Pull wire to confirm it is correctly inserted.
Push downward.
Terminal opener
WAGO connector
Wire
Twist
WAGO connector
SATO PARTS connector
Wire
Twist
Push downward.
Wire
Twist
Summary of Contents for FA-170
Page 30: ...2 WIRING 2 10 This page is intentionally left blank ...
Page 42: ...3 SETTINGS AND ADJUSTMENTS 3 12 This page is intentionally left blank ...
Page 63: ...D 1 15 Oct 2015 H MAKI ...
Page 64: ...D 2 3 Mar 2016 H MAKI ...
Page 65: ...D 3 3 Mar 2016 H MAKI ...
Page 66: ...D 4 3 Mar 2016 H MAKI ...
Page 67: ...D 5 3 Mar 2016 H MAKI ...
Page 68: ...D 6 20 Oct 2015 H MAKI ...
Page 69: ...D 7 Jan 9 03 ...
Page 70: ...D 8 15 Dec 2015 H MAKI ...
Page 71: ...D 9 15 Dec 2015 H MAKI ...
Page 72: ...Mar 27 07 R Esumi D 10 ...
Page 73: ...D 11 Feb 02 05 ...
Page 74: ...D 12 27 Aug 2015 H MAKI ...
Page 75: ...15 May 2014 H MAKI D 13 ...