2. INITIAL SETUP
12
1. Set your radar with 0.125 and 0.25 NM range and the head up mode.
The range scale can be selected two ways, as shown below. The slider bar can
be shown or hidden with [Show Scale Slider] in the [Settings] - [Radar] menu.
2. Turn the vessel’s bow toward a target.
3. Tap the [Home] icon to show the home screen and display mode settings.
4. Tap [Radar] to show the [Radar] menu.
5. Drag the [Radar] menu to show the [RADAR INITIAL SETUP] menu.
6. Tap [Antenna Heading Align].
7. Key in the offset value so that the target is displayed at the very top of the screen
(setting range: +179.9° to -180°, +: clockwise direction, -: counterclockwise direc-
tion), then tap the
icon.
8. Confirm that the target echo is displayed at correct bearing on the screen.
2.4
Check Points After Installation
Before using the product, carry out the following:
• Mechanical checks
• Turning the power on and initial setup
Mechanical checks
Check below points before switching on the .
000
010
020
030
040
050
060
070
080
090
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
000
010
020
030
040
050
060
070
080
090
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
Correct bearing of target
(relative to heading)
a
Displayed
position
of target
a
Target
Antenna oriented
to port
Picture appears with
clockwise deviation.
Displayed position of target
b
Target
b
Correct
bearing of
target
(relative to
heading)
Antenna oriented
to starboard
Picture appears with
counterclockwise deviation.
Zoom in
Zoom out
Method 1:
Pinch screen
Method 2:
Drag slider
(or tap bar or +, - icons)
3
NM
Zoom in
Zoom in
Zoom out
Zoom out