2. INITIAL SETUP
11
4. Drag the [Radar] menu display the menu item [Radar Initial Setup], then tap
[Radar Initial Setup].
5. Referring to the tables below, set up the radar.
[Radar] menu - [Radar Initial Setup]
[Radar] menu - [Antenna Position]
How to align the antenna heading
You have mounted the antenna unit facing straight ahead in the direction of the bow.
Therefore, a small but conspicuous target dead ahead visually should appear on the
heading line (zero degrees).
You may observe a minor bearing error on the display. This is due to the difficulty in
orienting the radar accurately. The following adjustment will compensate for the error.
Menu item
Description
[Antenna Rotation]
Select the antenna rotation speed from [Auto] or [24
RPM]. The default setting is [Auto].
[Antenna Heading Align]
See "How to align the antenna heading" on page 11.
[Main Bang Suppression]
If main bang appears at the screen center, slide the circle
icon so that the main bang disappears, while watching the
radar echo at the left-hand side of the display.
[Enable Sector Blanking]
Up to two sectors may be selected for blanking (no trans-
mission). Select [ON] to enable this feature. Set the start
and end angles (0° to 359°).
[Enable Sector 2 Blanking]
Menu item
Description
[Longitudinal (from bow)]
Referring to the figure on the right, enter
the radar antenna positioning bow-stern
(Longitudinal) and port-starboard (Lateral)
position from the origin.
[Lateral (-Port)]
[Antenna Height]
Select the height of the antenna above the waterline from
[Under 3 m], [3 m - 10 m] or [Over 10 m].
[Auto Tuning]
Enable/disable auto tuning for the connected radar.
[Tuning Source]
For dual-range display, select the range to use as the
manual tuning source.
[Manual Tuning]
Manually tune the radar. Not available when [Auto Tuning]
is enabled.
[Radar Monitoring]
Display various information regarding the connected ra-
dar.
[Radar Optimization]
Automatically adjust magnetron output and tuning for the
connected radar.
Note:
Be sure to perform [Radar Optimization] after re-
placing the magnetron.
[ARPA Advanced Settings] Do not change these settings.
[Set Hardware To Factory
Default]
Resets the radar selected at [Radar Source] to factory de-
fault.
[Reset Default Settings]
Resets [Radar] menu settings to default.
Origin