![Furuno CHS-5LMARK-2-55 Operator'S Manual Download Page 75](http://html.mh-extra.com/html/furuno/chs-5lmark-2-55/chs-5lmark-2-55_operators-manual_2350618075.webp)
8. MAINTENANCE, TROUBLESHOOTING
8-5
8.6
Troubleshooting
The table below provides common symptoms of equipment troubles and the means to
rectify them.
Symptom
Check, Remedy
Cannot turn on the
power
• Check power cable.
• Check ship's mains.
• First check the fuse in the processor unit. If it is OK, have a qual-
ified technician check the fuse in the transceiver unit.
Bottom echo be-
comes irregular
• Rough seas. Distance to the bottom changes due to rolling and
pitching.
• Long range selected. Transmission period is longer so ship's
pitching and rolling are apt to affect detection of echo.
Weak echo
• Output power set to minimum. Set [TX OUTPUT] ([SONAR]
menu) to maximum.
• Excessive TVG. Readjust TVG NEAR and FAR on the [SO-
NAR] menu.
Somewhat strange
color
• Brilliance too low. Adjust display brilliance.
Picture contains
noise
• Equipment not grounded properly. Check equipment ground.
• Power cable is too close to the signal cable. Relocate power ca-
ble or signal cable.
• Debris may be on sea surface. Reject unwanted noise with the
interference rejector on the [SONAR] menu.
Picture does not
change when tilt
angle is changed
• Problem in tilt mechanism or control line. Contact a FURUNO
agent or dealer for advice.
Summary of Contents for CHS-5LMARK-2-55
Page 8: ...TABLE OF CONTENTS vi APPENDIX 1 MENU TREE AP 1 SPECIFICATIONS SP 1 INDEX IN 1 ...
Page 12: ...SYSTEM CONFIGURATION x This page is intentionally left blank ...
Page 30: ...1 OPERATIONAL OVERVIEW 1 18 This page is intentionally left blank ...
Page 38: ...2 FINE TUNING THE SONAR PICTURE 2 8 This page is intentionally left blank ...
Page 54: ...4 ECHOSOUNDER MODE 4 6 This page is intentionally left blank ...
Page 70: ...7 MARKS AND SYSTEM MENUS 7 6 This page is intentionally left blank ...
Page 82: ...8 MAINTENANCE TROUBLESHOOTING 8 12 This page is intentionally left blank ...