Placement after lifting
Front of RV
Dragging or sliding
is forbidden
NOTE
It is forbidden to drag the air conditioner, which will damage
the box sponge at the bottom and further result in water
leakage caused by untight sealing of the sponge after
installation.
4. Install the panel assembly into the RV. The panel
assembly contains fasteners for the installation of air
conditioner, which will be used inside the RV, as shown in
the following figure:
All cardboards should be recycled
5. In case any deviation is found at the position of outdoor
unit on the roof during panel installation, the outdoor unit
of air conditioner can be finely adjusted internally through
the mounting hole (the box sponge on the roof must be
aligned with the 141/8" x 141/8" (362x362mm) square hole).
Installation of Air Duct and Top Fixing Plate
1.
Take out the panel and accessories for installation in the
carton;
2. Reach into the return air inlet of air conditioner and
pull down the wire harness of outdoor unit of the air
conditioner (heat pump model also has four-way valve
connecting wire and sensor lead, and electric heating
model also has electric heating connecting wire) for the
convenience of subsequent connection, as shown in the
following figure:
Measure the
ceiling thickness
Return air inlet of
air conditioner
Pull down the wire harness
of outdoor unit
3. Measure the thickness from ceiling to roof to select the
appropriate air duct sponge:
–
Air duct sponge (including 3 thickness specifications,
i.e., 15mm, 30mm and 45mm)
NOTE: Air duct sponge in the middle part is to keep
the sponge from deformation, which should be
removed during installation.
–
If the distance is 26-30mm, choose the air duct
sponge with a thickness of 15mm;
–
If the distance is 30-40mm, choose the air duct
sponge with a thickness of 30mm;
–
If the distance is 40-60mm, choose the air duct
sponge with a thickness of 45mm;
–
If the distance is greater than 60mm, the air duct
sponges with a thicknesses of 15mm, 30mm and
45mm shall be used in a combined manner according
to the actual situation;
–
If the distance is greater than 100mm,
an optional pipe joint should be used.
Chassis of the outdoor unit of
air conditioner
The sponge in the middle part
should be removed during
installation.
4. Select the correct air duct sponge, remove the middle
part, and paste it on the fixing plate along the air outlet
(the through hole on the sponge should correspond to
the hole on fixing plate), as shown in the following figure:
The through hole of air duct sponge
should correspond to the hole on
fixing plate
Air outlet
5. Make the arrow on the fixing plate towards the head
of the RV, cover the fixing plate into the 141/8" x 141/8"
(362x362mm) opening on the ceiling, and fix the fixing
plate with the outdoor unit of air conditioner on the roof
with 4 long bolts.
English
Rev: 06-30-22
- 5 -