Furrion 2021132274 User Manual Download Page 12

Installation and Replacement of the 
Battery of Remote Controller

1.

Open the battery cover: hold the handle of the battery
cover,gently pull it up, and remove the battery cover.

2. Put in the battery (AAA): pay attention to the polarity

of battery, which should be consistent with the
identifications in the battery box.

3. Install the battery cover.
4. Inspection: if there is no display on the display screen of

remote controller after pressing the button “ ”, please
reinstall the battery.

Display of the Display 
Board of Decorative Panel 
and Function Description:

Temperature and
error code display

Power light

Compressor operation
indicator light

LED strip indicator light

Temperature and error code display: 

used to set the 

display of temperature, room temperature and error code. 

Power light:

 when the machine is started up, the power 

light will be on. When it’s shut down, the power light will go 
out. 

Compressor operation indicator light:

 it will be on 

when the compressor is turned on, and go out when the 
compressor is turned off.

Urgency ON/OFF button:

 it’s on the display board,used to 

start up/shut down the machine urgently when the remote 
controller is lost.

Urgency ON/OFF
button

MAINTENANCE OF AIR CONDITIONER

Cleaning of Filter Screen

Position of left and right buckles of the decorative panel 
Regularly remove the filter screen behind the decorative 
panel inside the panel (press the left and right buckles of the 
decorative panel, and the decorative panel can be removed), 
flush it backwards with clear water, dry it and reinstall it.

NOTE: 

It is forbidden to operate the air conditioner without 

the filter screen, otherwise, the evaporator coil will be defiled 
and the service life of air conditioner will be affected.

Panel Surface Cleaning

Clean the outer surface of the panel with soft cloth dipped in 
neutral detergent. Do not use polishing or cleaning powder.

Fan Motor

The fan motor has been lubricated before leaving the factory 
and does not need special maintenance.

Position of left and
right buckles of
the decorative
panel

Filter screen

Decorative panel

Head direction of the RV

Display Board

English

Rev: 06-30-22

 

- 11 -

CCD-0005745 

Summary of Contents for 2021132274

Page 1: ...9K 12K BTU ROOFTOP AIR CONDI TIONER MODEL FACR09SM PS FACR12SM PS FACTRCSM PS LIPPERT NO 2021132274 2022107892 2021132281 USER MANUAL Product picture for reference only REV 06 30 2022 CCD 0005745...

Page 2: ...oduction of Air Conditioner 2 User Guide 2 Main Parameters 2 INSTALLATION INSTRUCTIONS 3 Precautions 3 Installation Position 3 Preparation for Installation 4 System Wiring 6 CONTROL INSTRUCTIONS 8 Des...

Page 3: ...reduce the heat entry of RV and improve work efficiency Park the RV in a cool place Strengthen thermal insulation of the compartment remove or block the opening in the vehicle and block the window wi...

Page 4: ...ed in other positions it is recommended to take the following measures 1 For the installation of a single air conditioner the air conditioner should be installed at a position slightly ahead of the ce...

Page 5: ...20A delay action circuit breaker Ensure that the wire extends into the roof opening by at least 380mm which can facilitate the installation of air conditioning equipment After the ventilator is remove...

Page 6: ...wnthewireharness ofoutdoorunit 3 Measure the thickness from ceiling to roof to select the appropriate air duct sponge Air duct sponge including 3 thickness specifications i e 15mm 30mm and 45mm NOTE A...

Page 7: ...arnessof four wayvalve Maintenanceport ofcontrolbox Correspondingterminal oncontrolbox 1 First of all remove the maintenance plate of the maintenance port of control box Introduce the main power line...

Page 8: ...in place and then install the lamp board on the panel when installing the decorative panel first clamp the two buckles in arrow direction on the corresponding holes of the panel and then clamp the rea...

Page 9: ...up the time the air conditioner stops 6 LIGHT Switch on the light or UPI than what unit has this function 7 TEMP Set temperature unit to or 8 UP Increase the temperature and time 9 ON OFF Turn on or t...

Page 10: ...d the air conditioner will operates in this mode by memory Fan mode FAN FAN MODE HEATER SLEEP CLOCK TIMER LOCK LIGHT 0 0 C F 1 Press the ON OFF button switch on the air conditioner it will run by memo...

Page 11: ...et up the time air conditioner switch off Press the button each time adjusting up 1 hour Press the button each time adjusting up 1 minute When the time is over the air conditioner will be switched off...

Page 12: ...turned on and go out when the compressor is turned off Urgency ON OFF button it s on the display board used to start up shut down the machine urgently when the remote controller is lost UrgencyON OFF...

Page 13: ...be repaired by qualified personnel ERROR CODE OF DISPLAY BOARD Code Cause Solution E1 Fault of indoor temperature sensor Check the sensor butt joint and replace the temperature sensing head E2 Fault...

Page 14: ...STALLATION EXPLODED DRAWING RoofofVR Outdoorunitof airconditioner Airductsponge Fixingplate Filterscreen Decorativepanel Panel Controlbox Longbolt Screw Displayboard English Rev 06 30 22 13 CCD 000574...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...entation has been provided Any unauthorized use shall void any applicable warranty The information contained in this manual is subject to change without notice and at the sole discretion of Lippert Re...

Reviews: