GREEN - OK
YEL- LIMITED
RED - NOT OK
100 105 110 115 120 125 130 135
LOW
EVS
WITHIN
REG
PROTECTION
OK
HIGH
EVS
EXTREME
CURRENT
INCOMING VOLTAGE
120 VAC LINE VOL
TAGE REGULATOR
REGULATED OUTLET
15 AMPS
PUSH TO RESET
M-8x AR
ON
OFF
15A 120V 50-60 Hz
MAIN POWER
www.furmansound.com • 877-486-4738
2
Please read IMPORTANT SAFETY INSTRUCTIONS
• No serviceable parts.
• Please inspect the unit thoroughly.
• Please contact Furman Customer Service at 800-472-5555, if there is any noticeable damage to product or product does not operate correctly.
Contents of this package include:
• M-8x AR
• Instruction Manual
BEFORE YOU BEGIN, INSPECT UPON RECEIPT
The Furman M-8x AR Voltage Regulator is intended to protect sensitive electronic equipment from problems caused by AC line voltage irregularities such
as brownouts, sags, and over-voltage conditions. Such irregularities can cause audio tonal changes, digital equipment malfunctions (such as loss of MIDI
programs or other data), or in extreme cases, permanent damage. The M-8x AR can accept input voltages over a wide range (see tables below) and convert
this to a steady, stable /- 5V output.
AC LINE VOLTAGE REGULATOR
The M-8x AR has eight receptacles on the rear panel, and one on the front panel, all are functionally in-
terchangeable. The receptacles are regulated, spike-suppressed, and filtered against RFI with a 3-pole
filter, making the M-8X AR a full-function power conditioner. The M-8x AR has no external controls
other than an on-off switch.
Note: The M-8x AR is designed for use with AC voltage only and DC voltages should never be applied.
Also, the M-8x AR does not change or regulate the line frequency in any way. The output frequency will
always be the same as the incoming line frequency.
Maximum and Minimum Load:
The M-8x AR can handle loads totaling up to 15 amperes as long as the input voltage is greater than or
equal to 124 Volts. For voltages below 124 Volts, the nominal 15 Amp current handling capacity must
be de-rated at approximately 113 milliamps per volt below 124 VAC.
To successfully handle worst-case brownout conditions, you should plan your total load so that it does
not exceed 12 amps, or 1400 watts under brownout conditions. Please note that the total load refers
to the combined current demand of all devices plugged into the M-8x AR, not just each individual
receptacle, or load.
75 80 90 100 110 120 130 140 145 160
140
130
120
110
100
90
80